Hitachi RAS-80YHA instruction manual Attaching the AIR Cleansing and Deodorizing Filters

Page 20

ATTACHING THE AIR CLEANSING AND DEODORIZING FILTERS

CAUTION

Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply.

1

2

3

Open the front panel.

Pull up the front panel by holding it at both sides with both hands.

Remove the filter.

Push upward to release the claws and pull out the filter.

Attaching the air cleansing and deodorizing filters to the filter.

Attach the air cleansing and deodorizing filters to the frame by gently compress its both sides and release after insertion into filter frame.

Claws

(4 places)

CAUTION

Do not bend the air cleansing and deodorizing filter as it may cause damage to the structure.

4

Attach the filters.

Attach the filters by ensuring that the surface written “FRONT” is facing front.

After attaching the filters, push the front panel at three arrow portion as shown in figure and close it.

NOTE

In case of removing the air-cleansing & deodorizing filters, please follow the above procedures.

The cooling capacity is slightly weakened and the cooling speed becomes slower when the air-cleansing & deodorizing filters are used. So, set the fan speed to "HIGH" when using it in this condition.

Air-cleansing & deodorizing filters are not washable and can be use in 1 year time. Type number for this air cleansing filter is <SPX-CFH13>. Please use this number for ordering when you want it.

Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur.

– 20 –

Image 20
Contents Indoor UNIT/OUTDOOR Unit Precautions During Operation Precautions During InstallationPrecautions During Shifting or Maintenance U T I O N Outdoor Unit Names and Functions of Each PartIndoor Unit Operation Indicator Indoor Unit IndicatorsSTART/STOP button Various Functions Automatic OperationStart StopHeating Operation Start StopDehumidifying Operation StopCooling Operation CoolFAN Operation HOW to SET the Timer Time, Day, MonthLights. a beep occurs Timer lamp lights on the indoor unit HOW to SET the Sleep Timer Explanation of the sleep timer Adjusting the AIR Deflector HOW to Exchange the Batteries in the Remote Controller Ideal Ways of Operation VentilationFor USER’S Information UV-LEDAttaching the AIR Cleansing and Deodorizing Filters Maintenance AIR FilterWashable Front Panel Maintenance AT Beginning of Long OFF Period Regular InspectionCondition Check the Following Points After Sale Service and WarrantyWhen Asking for SERVICE, Check the Following Points Memo Memo