FRONT/REAR VIEW
ZZ
I
H
G
F
E
B
A
C
D
5
J
K
L
A.WEATHER AND TIME IN
• Stops the clock’s alarm temporarily
• Activates a backlight for 5 seconds
C.CHANNEL button
• Recalls a different remote sensor reading – 1,2 or 3
• Activates the remote channels
• Activates the remote channels search
D.MEM button
• Toggles between current, minimum, maximum readings of the indoor and remote temperature & humidity
• Clears the temperature and humidity memory
E. DOWN ( ) button
• Decreases the parameters
• Activates manual remote channels search
• Disables time alarms (W) and (S) and Ice Warning Alarm
F. MODE button
• Toggles between time modes - time with seconds and time with the day of the week
• Activates clock’s manual programming mode
G.TEMP AL button
• Activates a Programmable Temperature Alarm Mode for all three remote channel
H.UP ( ) button
•Increases the parameters
•Activates US Time Zone selection mode
•Activates manual search for atomic time signal
•Enables time alarms (W) and (S) and Ice Warning Alarm
I. ALARM button
•Allows toggling between the calendar display and three time alarm modes
•Allows programming available alarms
J.WALL- MOUNT RECESSED HOLE
•Keeps the unit on the wall
K.BATTERY COMPARTMENT
•Accommodates 2 (two)
L.REMOVABLE TABLE STAND
•Holds unit in upright position on a flat surface
6
REMOTE SENSOR
FEATURES
•New
•Remote temperature and humidity transmission to the main unit via 433 MHz frequency
•Case can be wall mounted using
•Selection of the temperature display in Celsius or Fahrenheit
•Three channel selection
•LCD displays temperature, humidity and channel
E
A F
C D
B
A.LED INDICATOR
•Flashes once when the remote sensor transmits a reading to the main unit.
•Flashes twice when battery power is low.
B.BATTERY COMPARTMENT
•Holds two
C.RESET
•Resets all previous settings
D.CHANNEL SWITCH
•Selects the desired channel
E.
•Keeps the remote sensor on the wall
F.°C/ °F SWITCH
•Selects the temperature display in Celsius or Fahrenheit
7
BEFORE YOU BEGIN
• We recommend using alkaline batteries for the remote sensor and main unit when temperatures are above 32°F (0°C). We recommend using lithium batteries for the remote sensor when temperatures are below 32°F (0°C).
• Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements).
• ALWAYS install batteries in the remote sensor before the main unit.
• Insert batteries before first use, matching the polarity in the battery compartment
• Press RESET after each battery change with a paper clip or similar tool.
• Remove protective plastic screen from LCD display (if any).
• During an initial setup, place the main unit close to the remote sensor.
• After reception is established (the remote temperature will appear on the main unit’s display), position the remote sensor and the main unit within the effective transmission range of 328 feet (100 meters).
• The remote sensor can be placed indoors or outdoors, depending on the area where the temperature and humidity are intended to be measured. If you intend measuring outdoor elements, place remote sensor outdoors.
• The main unit must be placed indoors.
NOTE:
1.Avoid pressing any buttons on the main unit before the remote readings are displayed.
2.The effective operating range may be influenced by the surrounding building materials and how the receiver and transmitter are positioned.
3.Place the remote sensor so that it faces the main unit (receiver), minimizing obstructions such as doors, walls, and furniture.
4.Though the remote sensors are
8