Setup

Pressure Fed Models (FIG. 6)

NOTE: In the following instructions, the fill line refers to the inlet line.

5

1

6

 

3

 

2

FIG. 6

1.Remove and discard the inlet plug (1) and outlet plug (5).

2.Apply thread sealant (user supplied) to fill line fitting.

3.Connect fill line to inlet (2).

4.Torque fill line fitting to 85 + 10 in. lbs (9.60 + 1.13 N.m).

5.If installed, open oil supply valve located upstream from the pump.

6.Operate the hand priming assembly (3) until the oil expelled from the outlet (6) if free of air.

Alarm Pump Models (FIG. 7)

3

1

2

FIG. 7

1.Remove the sight well plug (1).

2.Fill the sight well (2) to the top with appropriately fil- tered oil.

3.Apply thread sealant (user supplied) to sight well plug (1).

4.Replace the sight well plug (1), taking care to not allow any thread sealant into the sight well (2).

5.Torque sight well plug (1) to 35 + 5 in. lbs (3.95 + 0.6 N.m).

3A2257C

7

Image 7
Contents Pressure Models Alarm Pump ModelSuction Models Gravity ModelsSkin Injection Hazard Equipment Misuse Hazard Mounting Pump Pressure Relief ProcedureSetup Gravity Fed Models FIG Suction Fed Models FIGPressure Fed Models FIG Alarm Pump Models FIGAdjusting the Pump Calculating Pints per Day Calculating Output CapacityMin Max SpecificationsInches Psi Bar MinProblem Cause Solution TroubleshootingSight Well Runs Dry MaintenanceSight Glass Replacement Kit Sight Well Fills With OilMetric Technical DataPump Dimensions Gravity Fed Pressure FedSuction Fed Alarm Pump Graco Information Graco Standard Warranty