Graco 24J393, 24J395, 24K466, 24J392, 24J397 Calculating Output Capacity, Calculating Pints per Day

Page 9

3.For Suction Fed and Gravity Fed models only: With the lubricator operating, count the drops from the drip tube (4) falling into the sight well (2) for one minute.

Setup

Calculating Output Capacity

The number of drops observed falling in the sight well equals the amount of oil discharged by the pump. The pump volume can be adjusted using the adjusting screw

(8)(FIG. 9) to change the piston stroke. (See Adjusting the Pump.)

Calculating Pints per Day

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿ ￿￿￿￿

￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿

4

2

FIG. 10

The number of drops seen falling in the sight well equals the amount of oil discharged by the pump. See Specifi- cations, page 10 for additional information on converting drops to volumetric output.

For Pressure Fed models only: Measure the output volume at the lube point.

4.If any further adjustment is necessary, repeat Steps 2 and 3.

5.Once the pump is adjusted to the proper specifica- tion, tighten the adjusting screw locknut (9) (FIG. 9).

NOTE: Piston stroke length set near zero may cause an inconsistent flow.

Calculating Minimum or Maximum Pump Output Capacity in Pints per Day

!￿￿￿￿￿"￿￿￿￿

￿

￿￿￿￿￿%￿￿￿￿￿

￿

￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿&

 

 

￿￿￿￿￿￿￿￿￿￿

#￿￿￿￿$￿￿￿￿

 

￿￿￿￿￿￿￿￿￿￿'￿(￿

 

 

 

 

￿￿￿￿￿￿￿￿￿￿&￿

 

 

 

 

 

 

￿￿￿￿￿%￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

 

 

 

 

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

*Minimum and Maximum drops per stroke listed in Specifications, page 10.

Example:

The following example calculates the maximum and minimum flow for a 1/4 inch pump model with an electric motor and 300:1 gear ratio.

To calculate the Maximum Flow:

1725 RPM

X

Max 12 drops

X

1440 min.

 

per stroke

300:1 Gear Ratio

 

 

Max 6.88

 

 

 

= Pints/day

14438(Number of Drops in a Pint)

To calculate the Minimum Flow:

Replace the maximum 12 drops per stroke (used in the equation above) with the minimum 2 drops per stroke = 1.17 minimum pints per day.

3A2257C

9

Image 9
Contents Suction Models Alarm Pump ModelGravity Models Pressure ModelsSkin Injection Hazard Equipment Misuse Hazard Mounting Pump Pressure Relief ProcedureSetup Gravity Fed Models FIG Suction Fed Models FIGPressure Fed Models FIG Alarm Pump Models FIGAdjusting the Pump Calculating Pints per Day Calculating Output CapacityInches Psi SpecificationsBar Min Min MaxProblem Cause Solution TroubleshootingSight Glass Replacement Kit MaintenanceSight Well Fills With Oil Sight Well Runs DryMetric Technical DataPump Dimensions Gravity Fed Pressure FedSuction Fed Alarm Pump Graco Information Graco Standard Warranty