Setup

Suction Fed Models (FIG. 4)

5

 

 

 

 

1

 

 

 

 

 

 

 

3

 

 

 

 

6

 

 

 

 

 

2

4

FIG. 4

1.Remove the sight well plug (1) and outlet plug (5). Discard outlet plug (5).

2.Fill the sight well (2) to the top with appropriately fil- tered oil.

3.Operate the hand priming assembly (3) until the oil level drops below the end of the drip tube (4).

4.Apply thread sealant (user supplied) to sight well plug (1).

5.Replace the sight well plug (1), taking care to not allow any thread sealant into the sight well (2).

6.Torque sight well plug (1) to 35 + 5 in. lbs (3.95 + 0.6 N.m).

7.Continue to hand prime until oil expelled from the outlet (6) is free of air.

8.If all oil is evacuated from sight well (2), repeat steps 2 - 7 as often as necessary, until all air has been expelled.

Gravity Fed Models (FIG. 5)

NOTE: In the following instructions, the fill line refers to the inlet line.

1

5

3

6

2

FIG. 5

1.Remove and discard the sight well plug (1) and out- let plug (5).

2.Fill the sight well (2) to the top with appropriately fil- tered oil.

3.Operate the hand priming assembly (3) until the oil level drops below the end of the drip tube (4) (FIG. 4).

4.Apply thread sealant (user supplied) to fill line fitting.

5.Connect fill line to sight well (2), taking care to not allow any thread sealant into the sight well.

6.Torque fill line fitting to 35 + 5 in. lbs (3.95 + 0.6 N.m).

7.If installed, open oil supply valve located upstream from the pump.

8.Continue to hand prime until oil expelled from outlet

(6)is free of air.

9.If all oil is evacuated from sight well, repeat steps 2 - 8 as often as necessary, until all air has been expelled.

6

3A2257C

Image 6
Contents Gravity Models Alarm Pump ModelSuction Models Pressure ModelsSkin Injection Hazard Equipment Misuse Hazard Pressure Relief Procedure Mounting PumpSetup Suction Fed Models FIG Gravity Fed Models FIGAlarm Pump Models FIG Pressure Fed Models FIGAdjusting the Pump Calculating Output Capacity Calculating Pints per DayBar Min SpecificationsInches Psi Min MaxTroubleshooting Problem Cause SolutionSight Well Fills With Oil MaintenanceSight Glass Replacement Kit Sight Well Runs DryTechnical Data MetricPump Dimensions Pressure Fed Gravity FedSuction Fed Alarm Pump Graco Standard Warranty Graco Information