Graco 247444, 247574 Pump Module Assembly, Models 247706 and 247707 only

Page 5

Pump Module Assembly

Models 247706 and 247707 only

For divider valve-based automatic lubrication systems. (Unless otherwise indicated, see FIG. 1).

D

G

H

Pressure Relief

Kit 247902

P

Hydraulic Control

Module

ti11453

FIG. 1 Model 247706 shown

Pump Module Assembly

1.Install Pump (D) on Reservoir (P).

2.Remove Vent Valve Hydraulic Control (J) fitting and replace with Plug (R) (FIG. 6, page 9).

3.Install Hydraulic Control Module on Reservoir (P).

4.Connect Tank Line (G) to Pump (D).

5.Connect Pump High Pressure Hydraulic Line (H) to Pump (D).

6.Install Pressure Relief Kit (247902) to Pump Outlet.

7.Install model number label as shown in FIG. 2.

Install

Identification

Label Here

FIG. 2

312349G

5

Image 5
Contents Single Line Parallel Automatic Lubrication Systems Important Safety InstructionsSingle Line Series Progressive Lubrication Systems ModelFire and Explosion Hazard Pressurized Equipment Hazard Pump Module Overview UnpackingPump Module Capabilities Pump Module OperationModels 247706 and 247707 only Pump Module AssemblyGrounding for non-mobile installation InstallationVent Valve Kit for Custom Tank Installation Pump ModuleHydraulic Control Module Hydraulic Control Module for Custom Tank InstallationKey Typical InstallationVent Valve Installation Kit Control Module Installation Kit Custom Tank Installation Start-up Pressure Relief ProcedureOperation Fill Reservoir ShutdownProblem Cause Solution ServiceTroubleshooting Parts Drawing See Parts List,Vent Valve Kit 2 Control Module Kit 4 For models 247706 and 247707 only Pressure Relief Kit 5Part No. Description Qty Parts ListTechnical Data Mounting Diagram Dimensions ModelDimensions Dimensions 312349G Graco Information Graco Standard Warranty