Graco 247574, 247706, 247707, 247444 Hydraulic Control Module for Custom Tank Installation

Page 7

Hydraulic Control Module for Custom Tank Installation

(Unless otherwise indicated, see FIG. 5 and FIG. 6, page 9)

1.Mount control module on a flat, sturdy surface per the recommended configuration (Fig. 2, page 8).

2.Connect Pump Tank Line (G) to pump hydraulic outlet port.

3.Connect Vent Valve Hydraulic Control (J) connection to the hydraulic control line (A).

4.Connect the Pump High Pressure Hydraulic Line

(H) to the pump hydraulic input port.

5.Connect high pressure hydraulic supply to the High Pressure Hydraulic Connection (L) and the tank lines to the Hydraulic Tank Connection (K).

6.Connect the 3-way Solenoid Valve (P) to the timer.

Coil should always be installed with lettering facing out.

Installation

Hydraulic Control Module 247705

(For Single-line, Progressive, Automatic Lubrication Systems with refinery reservoir installation)

(Unless otherwise indicated, see FIG. 5 and FIG. 6, page 9)

1.Mount control module on a flat, sturdy surface. The 6-foot hydraulic supply and hydraulic tank line must reach the pump when installed in the refinery reservoir.

2.Connect Pump Tank Line (G) to pump hydraulic outlet port.

3.Remove Vent Valve Hydraulic Control (J) and add plug (R) to vent port.

4.Connect the Pump High Pressure Hydraulic Line

(H) to the pump hydraulic input port.

5.Connect high pressure hydraulic supply to the High Pressure Hydraulic Connection (L) and the tank lines to the Hydraulic Tank Connection (K).

312349G

7

Image 7
Contents Model Important Safety InstructionsSingle Line Parallel Automatic Lubrication Systems Single Line Series Progressive Lubrication SystemsFire and Explosion Hazard Pressurized Equipment Hazard Pump Module Operation UnpackingPump Module Overview Pump Module CapabilitiesModels 247706 and 247707 only Pump Module AssemblyPump Module InstallationGrounding for non-mobile installation Vent Valve Kit for Custom Tank InstallationHydraulic Control Module Hydraulic Control Module for Custom Tank InstallationKey Typical InstallationVent Valve Installation Kit Control Module Installation Kit Custom Tank Installation Operation Pressure Relief ProcedureStart-up Fill Reservoir ShutdownTroubleshooting ServiceProblem Cause Solution Parts Drawing See Parts List,Vent Valve Kit 2 Control Module Kit 4 For models 247706 and 247707 only Pressure Relief Kit 5Part No. Description Qty Parts ListTechnical Data Mounting Diagram Dimensions ModelDimensions Dimensions 312349G Graco Information Graco Standard Warranty