Midland Radio P25 operation manual Selecting Digital Talk Group

Page 30
Press key
until
“Group:” is
displayed
Enter new talk group then press
OK
Figure 4.18 – Talk group selection using key

Syn-Tech III P25 Portable Radio

OPERATION MANUAL

4.1.7Selecting Digital Talk Group

The default talk group may be set for the channel in radio programming. When the channel is selected, the default talk group is used. If a default talk group has not be set for the channel, the radio will use the talk group last selected and displayed.

Each zone in the radio may have a list of allowed talk groups. When the radio is in digital transmit mode, you may select a new talk group from this list by repeatedly

pressing the (star) key until “GROUP:” is displayed. Then use the alpha-numeric keypad to enter the new talk group. Then press the left soft key (OK) to use the entered talk group. If the

entered talk group is not in the zone’s talk group list, the radio will not allow the talk group selection.

Each zone in the radio may have all valid talk groups assigned to it. This allows any talk

group to be selected by repeatedly pressing the (star) key until “GROUP:” is displayed. Then use the alpha-numeric keypad to enter the new talk group. Then press the left soft key (OK) to use the entered talk group.

The radio has a talk group scan feature which is on by default. When a signal is received from any talkgroup in the list, the radio will switch to the received talkgroup for the duration of the receive signal and then start the scan delay timer. You may reply using the received talk group during the scan delay time, by pressing PTT. After the scan delay time expires the radio will switch back to the selected talk group. Use MENU CHANNEL PARAMETERS GROUP SCAN to turn talk group scan on/off.

680-090-2041

22

Version 5.0

http://www.midlandradio.com

 

Image 30
Contents Midland Syn-Tech III P25 Portable Radio Preface Customer AssistanceImportant Safety Information General Precautions FCC Exposure Statements Patent and Copyright StatementsProduct Features Abbreviations and Acronyms Radİo Controls and Indİcators Table of Contents IntroductionGettİng Started OperationWarranty Statement Package Contents Installing the Battery Getting Started Installing the AntennaInstalling and Removing the Battery Removing the BatteryInstalling the Belt Clip Charging the BatteryRadio Controls and Indicators Side, Top and Front Views Emergency Call Button Channel SwitchButton and Key Functions Alpha-Numeric keypadRight soft key Index Power Adjust long press/Mode Change short press keyKeypad Lock short press/Emergency Reset long press key Monitor long press/Call Wait Option short press keyEntering/Exiting Talkaround Mode Switching Talk GroupEntering/Exiting Unaddressed Voice Call Mode Scan keySetting Current Status Switching to Home Zone and ChannelSwitching Zones Entering Unacknowledged Individual Call ModeSending a Call Alert Transmitting a Selective CallTransmitting a 2-Tone Call Alpha-numeric Keypad Entry Alpha-numeric Keypad Entry KeysDisplay Icons Syn-Tech III P25 Portable Radio Basic Operation Turning the Radio On and OffZone selection using # key Selecting ZonesZone selection using Menu Channel switch selection Selecting ChannelsReceiving Signals Analog ReceptionDigital Reception Transmitting to Other Radios Analog TransmissionsDigital Transmissions 14 Digital transmit displayTime Out Time Busy Channel LockoutSelecting Transmit Power Power Adjust/Mode Change key for more than one secondSelecting Digital Talk Group Channel Parameters Groups Selecting Talkaround Transmit Mode Enter to TalkaroundMonitoring Channels 22 Monitoring channel23 Monitoring all talk groups and NACs Selecting Digital Call Wait Option Short pressScanning Channels Transmitting While Scanning26 Pressing PTT while scan is paused Editing the Scan List 27 Editing the zone’s scan listLocking the Keypad 28 Locking the keypadSwitching to the Home Zone and Channel 29 Switching to the home zone and channelAdvanced Operations Receiving Emergency CallsTransmitting Emergency Calls Press of the Keypad Lock key or by turning the radio offReceiving Digital Individual Calls Receiving Unacknowledged Individual CallsReceiving Acknowledged Individual Calls 34 Receiving acknowledged individual callTransmitting Digital Individual Calls Transmitting Unacknowledged Individual CallsTransmitting Acknowledged Individual Calls 37 Transmitting acknowledged individual call39 Exiting unaddressed call mode Transmitting Digital Unaddressed CallsTransmitting Digital Telephone Interconnect Calls 40 Initiating telephone interconnect requestReceiving a Digital Call Alert Transmitting a Digital Call AlertReceiving and Sending Non-voice Messages Receiving SMS Messages Menu SMS Received MessagesSending SMS Messages 45 Sending SMS messageReceiving Predefined Messages 46 Received predefined messageSending Predefined Messages 47 Sending predefined messageSetting Present Status 9.6 Receiving StatusSending Status Status Request will not appear on the Status menuRequesting Status 51 Requesting statusChannel Programming 52 Channel programmingAnalog Mode Menu Tree Menu OperationSoftware Digital Mode Menu Tree Predefined Messages Channel Parameters Accessories Accessory Midland P/NYour radio does not require any periodic maintenance Troubleshooting Problem Possible CAUSEs SOLUTIONsWeight with antenna and without battery Symbol RateDimensions without battery HxWxL ModulationESD MIL-STD 810C MIL-STD 810D MIL-STD 810E MIL-STD 810FVHF UHF RMS Error Transmitter SpecificationsRated RF Output Power Frequency Stability Modulation Limiting Analog 25 kHz channelWarranty Statement Parretta Drive Kansas City, MO