Bard MIS-656 Wall Mount General Information, AIR Conditioner Wall Mount Model Nomenclature

Page 4

WALL MOUNT GENERAL INFORMATION

AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE

MODEL NUMBER

WA 37 2 – A 10 X X X X X A

CONTROL MODULES

(See Spec. Sheet S3208)

CAPACITY

 

25

-

2 Ton

REVISIONS

37

-

3 Ton

KW

COLOR OPTIONS

X -

Beige (Standard)

1 -

White

COIL OPTIONS

X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator

and Condenser

VOLTS & PHASE A - 230/208/60/1 B - 230/208/60/3 C - 460/60/3

VENTILATION OPTIONS

X - Barometric Fresh Air Damper

(Standard)

B - Blank-off Plate

M - Motorized Fresh Air Damper

V- Commercial Room Ventilator - Motorized with Exhaust

E- Economizer (Internal - Fully Modulating with Exhaust

R- Energy Recovery Ventilator - with Exhaust

2

- Mesa Brown

4

- Buckeye Gray

5

- Desert Brown

6

- Dark Bronze

FILTER OPTIONS

X- One Inch Throwaway (Standard)

W - One Inch Washable

P - Two Inch Pleated

OUTLET OPTIONS

X - Front (Standard)

T - Top on WA30 and WA37 Models

NOTE: For 0KW and circuit breakers (230/208 Volt) or pull disconnects (460 Volt) applications, insert 0Z in the KW field of model no.

TABLE 1 – ELECTRICAL SPECIFICATIONS

 

 

 

3

1

2

2

3

1

2

2

 

 

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

Minimum

External

Field Power

 

 

 

 

 

 

Maximum

 

 

Fuse

Ground

 

 

No.

 

Field

 

Circuit

or Ckt.

Wire Size

 

 

 

External

 

Ampacity

Breaker

 

 

Wire Size

 

Rated

Field

Minimum

Fuse or

Power

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

Volts/

Power

Circuit

Ckt.

Wire

Wire

CKT

CKT

CKT

CKT

CKT

CKT

CKT

CKT

Phases

Circuits

Ampacity

Breaker

Size

Size

A

B

A

B

A

B

A

B

WA302-A0Z

 

1

24

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A05

230/208-1

1

31

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A10

1

57

60

6

10

NA

NA

NA

NA

NA

NA

NA

NA

A15

 

1 or 2

83

90

4

8

55

26

60

30

4

10

8

10

WA302-B0Z

 

1

17

20

12

12

NA

NA

NA

NA

NA

NA

NA

NA

B09

230/208-3

1

32

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

B15

 

1

50

50

8

10

NA

NA

NA

NA

NA

NA

NA

NA

WA302-C0Z

 

1

10

15

14

14

NA

NA

NA

NA

NA

NA

NA

NA

C09

460-3

1

17

20

12

12

NA

NA

NA

NA

NA

NA

NA

NA

C15

 

1

26

30

10

10

NA

NA

NA

NA

NA

NA

NA

NA

WA372-A0Z

 

1

28

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A05

 

1

32

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A08

230/208-1

1

47

50

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A10

 

1

58

60

6

10

NA

NA

NA

NA

NA

NA

NA

NA

A15

 

1 or 2

84

90

4

8

58

26

60

30

6

10

10

10

WL372-B0Z

 

1

20

25

10

10

NA

NA

NA

NA

NA

NA

NA

NA

B06

230/208-3

1

24

25

10

10

NA

NA

NA

NA

NA

NA

NA

NA

B09

 

1

33

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

B15

 

1

51

60

6

10

NA

NA

NA

NA

NA

NA

NA

NA

WL372-C0Z

 

1

11

15

14

14

NA

NA

NA

NA

NA

NA

NA

NA

C06

 

1

12

15

14

14

NA

NA

NA

NA

NA

NA

NA

NA

C09

460-3

1

17

20

12

12

NA

NA

NA

NA

NA

NA

NA

NA

C12

 

1

21

25

10

10

NA

NA

NA

NA

NA

NA

NA

NA

C15

 

1

26

30

10

10

NA

NA

NA

NA

NA

NA

NA

NA

QMaximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.

R Based on 75° copper wire. All wiring must conform to the National Electrical Code and all local codes.

S These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), Article 310 for power conductor sizing. CAUTION: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of table 310 regarding Ampacity Adjustment Factors when more than three conductors are in a raceway.

Manual 2100-404

Page 2

Image 4
Contents WA372 Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersWall Mount General Information Electrical SpecificationsAIR Conditioner Wall Mount Model Nomenclature Dimensions of Basic Unit Nominal Back ViewGeneral Shipping DamageElectric Heat Table Fresh AIR Damper Assembly Duct WorkFresh AIR Intake Condensate DrainInstallation Instructions Wiring Main PowerWall Mounting Information Mounting the UnitWiring LOW Voltage Wiring Thermostat Wire SizeOperating Voltage Range Wall Thermostat and Subbase CombinationsMounting Instructions WALL-MOUNTING Instructions Common WALL-MOUNTING Installations Electric Heat Clearance LOW Voltage Wiring Start UP Pressure Service Ports Compressor Control ModuleTroubleshooting FAN Blade Setting DimensionsRemoval of FAN Shroud Refrigerant ChargeOutdoor Temperature F Cooling PressureOptional Accessories WA302-A WA372-A WA302-B WA372-B

MIS-656 specifications

The Bard MIS-656 is a state-of-the-art medical device designed for optimal performance in a variety of clinical settings. Specifically engineered for minimally invasive surgical procedures, the MIS-656 offers surgeons a range of advanced features that enhance precision, efficiency, and patient safety.

One of the standout characteristics of the Bard MIS-656 is its innovative imaging technology. It utilizes high-definition visualization that provides surgeons with clear and detailed images of the surgical field. This enables better identification of anatomical structures, reducing the risk of complications during procedures. The device also integrates advanced optics, allowing for an expanded field of view, which is crucial in minimally invasive surgeries.

In terms of ergonomics, the MIS-656 is crafted with the surgeon's comfort in mind. The device features a lightweight design that minimizes strain during extended operations. Its intuitive controls and adaptable design ensure that surgeons can easily maneuver the device, leading to reduced fatigue and increased focus on patient outcomes.

Another major advantage of the Bard MIS-656 is its versatility. The device is compatible with a range of surgical instruments, making it suitable for diverse surgical specialties, including gynecology, urology, and general surgery. This multi-functional capability allows hospitals to optimize their surgical instruments and improve overall operating room efficiency.

The MIS-656 also integrates seamlessly with digital documentation systems. This connectivity allows for real-time data capture and monitoring, facilitating better communication between surgical teams. Enhanced data tracking contributes to improved patient care and outcomes, as medical professionals can analyze trends and adapt procedures accordingly.

Safety is a paramount concern in surgical environments, and the Bard MIS-656 is equipped with features designed to minimize risks. Its robust design and advanced materials ensure durability, while safety mechanisms, such as failsafe locking systems, enhance operational reliability.

In summary, the Bard MIS-656 exemplifies innovation in minimally invasive surgical technology. With superior imaging capabilities, ergonomic design, surgical versatility, and commitment to safety, this device stands out as a valuable addition to modern operating rooms. As surgical techniques continue to evolve, the MIS-656 positions itself as a key asset for healthcare providers seeking to enhance surgical precision and patient care.