Bard WA482, WA421 Installation Instructions, Wall Mounting Information, Mounting the Unit

Page 9

INSTALLATION INSTRUCTIONS

WALL MOUNTING INFORMATION

1.Two holes for the supply and return air openings must be cut through the wall as shown in Figure 3.

2.On wood frame walls, the wall construction must be strong and rigid enough to carry the weight of the unit without transmitting any unit vibration.

3.Concrete block walls must be thoroughly inspected to insure that they are capable of carrying the weight of the installed unit.

MOUNTING THE UNIT

1.These units are secured by wall mounting brackets which secure the unit to the outside wall surface at both sides. A bottom mounting bracket is provided for ease of installation, but is not required.

2.The unit itself is suitable for 0 inch clearance, but the supply air duct flange and the first 3 feet of supply air duct require a minimum of 1/4 inch clearance to combustible material. If a combustible wall use a minimum of 30-1/2” x 10-1/2” dimensions for sizing. However it is generally recommended that a 1 inch clearance is used for ease of installation and maintaining the required clearance to combustible material. The supply air opening would then be 32” x 12”. See Figures 3 and 4 for details.

3.Locate and mark lag bolt locations and bottom mounting bracket location. See Figure 3.

WARNING

Failure to provide the 1/4 inch clearance between the supply duct and a combustible surface for the first 3 feet of duct can result in fire causing damage, injury or death.

4.Mount bottom mounting bracket.

5.Hook top rain flashing under back bend of top. Top rain flashing is shipped secured to the right side of the back.

6.Position unit in opening and secure with 5/16 lag bolts; use 7/8 inch diameter flat washers on the lag bolts.

7.Secure rain flashing to wall and caulk across entire length of top. See Figure 3.

8.For additional mounting rigidity, the return air and supply air frames or collars can be drilled and screwed or welded to the structural wall itself (depending upon wall construction). Be sure to observe required clearance if combustible wall.

9.On side by side installations, maintain a minimum of 20 inches clearance on right side to allow access to control panel and heat strips, and to allow proper airflow to the outdoor coil. Additional clearance may be required to meet local or national codes.

Manual 2100-218 Page 7

Image 9
Contents Models WA421 WA482 WA602Contents Getting Other Information and Publications Wall Mount General Information Heat Pump Wall Mount Model NomenclatureElectric Heat Table Front View Side View Back View Unit DimensionsSingle Circuit Electrical SpecificationsShipping Damage GeneralDuct Work Fresh AIR Intake FiltersCondensate Drain Fresh AIR DamperInstallation Instructions Wall Mounting InformationMounting the Unit Mounting Instructions Electric Heat Clearance See Mounting Instructions Wall Mounting InstructionsCommon Wall Mounting Installations Wiring LOW Voltage Wiring Wiring Main PowerThermostat Wire Size TAP RangeUnit 24V Terminal Board Start UP Service Hints Sequence of OperationCompressor Control Module Phase Monitor Pressure Service PortsTypical Settings for Dual Unit Installation FAN Blade Setting Dimensions TroubleshootingRemoval of FAN Shroud Refrigerant ChargeRecommended Airflow Maximum ESP of Operation Electric Heat onlyPressure Table Cooling Optional Accessories

WA482, WA421 specifications

Bard WA482 and WA421 are high-performance air conditioning units designed for commercial and industrial applications. These models are renowned for their exceptional cooling efficiency, durability, and versatile performance, making them suitable for a variety of settings, including schools, factories, and office buildings.

One prominent feature of the Bard WA482 is its powerful cooling capacity. It has an impressive cooling output that can effectively manage indoor temperatures, even in the hottest conditions. This capability ensures optimal comfort for occupants while maintaining energy efficiency. Similarly, the Bard WA421 offers substantial cooling capacity, catering to smaller commercial spaces without compromising on performance.

Both models utilize advanced technology to enhance their operational efficiency. The units are equipped with a high-efficiency scroll compressor that minimizes energy consumption while delivering consistent cooling. This technology allows businesses to reduce their energy costs significantly, contributing to environmental sustainability.

Another significant characteristic of Bard WA482 and WA421 is their robust construction. Built with heavy-gauge galvanized steel, these units are designed to withstand tough environmental conditions. This durability ensures a long operational life, reducing the need for frequent repairs and replacements. The units are also corrosion-resistant, making them ideal for coastal or humid regions.

Efficiency is further enhanced by the inclusion of a multi-speed fan that allows for better airflow management. This feature enables the units to adjust their functioning based on the current cooling demand, optimizing energy use and minimizing noise levels. Consequently, users experience a comfortable environment without disruptive sound.

Maintenance is made simple with these models thanks to their accessible design. The units feature removable panels that provide easy access to internal components for routine servicing. This design minimizes downtime and helps maintain the overall efficiency of the system.

In terms of versatility, Bard WA482 and WA421 can be customized with various kits and options, including digital thermostats and advanced control systems. This adaptability enables users to tailor the cooling solutions to their specific needs, enhancing overall satisfaction.

In summary, Bard WA482 and WA421 stand out in the commercial air conditioning sector due to their impressive cooling capacity, energy-efficient technologies, robust construction, and ease of maintenance. These characteristics make them a reliable choice for businesses looking to maintain a comfortable and sustainable indoor environment.