Stanley Black & Decker S200 Operating Instructions, Specifications, Warranty, Operating Tips

Page 2

Stanley Stud Sensor 200

The Stud Sensor 200 uses electronic signals to locate the center of studs, joists or live AC wires through drywall or other common building materials. Once the center of a stud has been detected in one pass across the surface, the Stud Sensor 200 gives a visual display and sounds an audible tone. A marking channel allows you to easily note the stud center and edges on the wall.

Note: Read all instructions prior to operating the Stud Sensor 200 and DO NOT remove any labels from the tool.

OPERATING INSTRUCTIONS

Battery

1Open door on back of unit and connect a 9 volt battery (not included) to clip. Put battery back into case and close back battery door.

Note: Recommend to replace a new 9 volt battery when low battery - “Low Battery” will appear on the LCD.

Usage

Detecting Wood / Metal Studs

2Hold the Stud Sensor 200 flat against the surface, making firm contact. 3 Press in and hold the activation button. A series of tones will sound. 4 When the unit is calibrated the “Ready” icon will appear on the LCD.

5Keep holding the activation button during all of the following procedures.

Note: 3 The unit cannot be moved before calibration is complete. 2 While calibrating, the Stud Sensor 200 must not be placed directly over a stud, dense material such as

relative position of the stud on the screen.

6When it detects the stud center, the “Center” icon will appear on the LCD and an audible tone will sound. Use the marking channel located at the top of the unit to mark the stud center.

Detecting Live AC Wires

10The live wire red LED will illuminate, the “AC” icon will appear on the LCD, and the Stud Sensor 200 sounds an audible tone, warning when in the proximity (typically within 4” to 18” along the surface) from a live wire.

Note: Static electrical charges that can develop on drywall and other surfaces will spread the voltage detection area many inches on each side of the actual electrical wire. To aid in locating the wire position, scan holding the unit ½” away from the wall surface or place your other hand on the surface approximately 12” from sensor.

Warning: Shielded wires or wires in metal conduits, casings, metallized walls or thick, dense walls will not be detected. Always turn off AC power when working near wiring.

Cautions on Operating

You should always use caution when nailing, cutting and drilling in walls, ceilings and floor that may contain wiring and pipes near the surface. Always remember that studs or joists are normally spaced 16 inches or 24 inches apart and are 1½ inches in width. To avoid surprises, be aware that anything closer together or of a different width may not be a stud.

Conventional Construction

Doors and windows are commonly constructed with additional studs and headers for added stability. The Stud Sensor 200 detects the edge of these double studs and solid headers as a single, wide stud.

Surface Differences

The Stud Sensor 200 will scan through common building materials, Including:

Gypsum drywall

Plywood sheathing

Hardwood floors

Linoleum over wood

Wallpaper

The scanner cannot scan through:

Carpeting

Foil faced materials

Ceramic tile

Cement or concrete

Metal & plaster walls

Wallpaper

There will be no difference in the function of the Stud Sensor 200 on surfaces covered with wallpaper or fabric unless the coverings used contain metallic foil or fibers.

Ceilings

When dealing with a rough surface such as a sprayed ceiling, utilize a piece of cardboard when scanning the surface. Run through the calibration technique described earlier with the piece of cardboard too, to assure best performance of the unit. Also, it is particularly important in this application to remember to keep your free hand away from the unit.

Note: The thickness, density and moisture content of the surface material will affect the sensing depth.

SPECIFICATIONS

(At 35-55% relative humidity)

Battery

9 volt (not included)

 

 

Depth Range

 

 

 

Wood or Metal Studs

Up to ¾” (19 mm) through drywall

 

 

Live AC Wires (120 volts AC)

Up to 2” (50 mm) through drywall

 

 

Accuracy - Stud Center

 

 

Wood

±1/8” (3 mm)

 

 

Metal

±1/4” (6 mm)

 

 

Operating Temperature

+32°F to +120°F (-0°C to +49°C)

 

 

Surface Temperature

-4°F to +150°F (-20°C to +66°C)

 

 

WARRANTY

Stanley Tools warrants the Stud Sensor 200 against defects in material and workmanship for one year from the date of purchase. Stanley’s liability under this warranty is limited the replacement of the unit. Any attempt to repair the product by other than factory authorized personnel will void this warranty. Calibration, batteries and maintenance are the responsibility of the user. Where permitted by law, Stanley is not responsible for incidental or consequential damages. Agents of Stanley cannot change this warranty. Stanley is not responsible for damage resulting from wear, abuse or alteration of this product. The user is expected to follow ALL operating instructions. This warranty may provide you with additional rights that vary by state, province or nation.

WARNING:

Protect Your Eyes, Wear Safety Goggles.

metal, or over a wet or newly painted area, or it will not properly calibrate. 11 If all segments of the LCD flash on and off when the activation button is pressed, move the Stud Sensor 200 to a different location and try again. Releasing the activation button will turn off the sensor.

6Slide the Stud Sensor 200 slowly across the surface in a straight line. 9 As it detects a stud, the Stud Sensor 200 will display the

OPERATING TIPS

The Stud Sensor 200 is designed for use only on interior surfaces.

Prevent Interference

To ensure best performance from the Stud Sensor 200, keep your free hand at least 6 inches away from the unit and wall surface while testing or scanning surfaces.

IMPORTANT SAFETY NOTICE

Insure proper detection of live wires. Always hold the Stud Sensor 200 in the handle area only. Grasp between fingers and thumb while making contact with your palm.

©2012 STANLEY TOOLS

www.STANLEYTOOLS.com

701 East Joppa Road

Towson, Maryland 21286

Image 2
Contents S200 Important Safety Notice SpecificationsWarranty Operating InstructionsGarantía Instrucciones DE OperaciónEspecificaciones Consejos DE OperaciónImportant Avis DE Sécurité Instructions DE FonctionnementConseils DE Fonctionnement Fiche Technique