| ACCESSORIES |
| ||
|
|
|
|
|
|
SPOOL GUN ADAPTER KIT
(K1700-1) (Included in the K1692-1)
WARNING
Remove all input power to the PM 255 before pro- ceeding.
The Spool Gun Adapter Kit provides direct connection and use of the
It also provides gun trigger switch transfer between the machine’s use with its feeder gun or the spool gun for same polarity welding with different wire and gas processes.
The kit includes a spool gun adapter module assem- bly with a single connecting plug, a rear gas inlet set- ting with hose and mounting hardware with installation and operation instructions.
CAUTION
The spool gun module is intended for use with Prince™ Spool Guns only. Use with other units may cause damage to the equipment. For Spool Gun operation, refer to the instruction manual pro- vided with the Prince™ Spool Gun. (IM599), MK
MAKING A WELD WITH THE SPOOL GUN, SPOOL GUN
NOTE: The
CAUTION
Closing either gun trigger will cause the electrode of both guns to be electrically “HOT”. Be sure unused gun is positioned so electrode or tip will not contact metal case or other metal common to work.
1.Pulling the trigger for the
a.Disables spool gun operation.
b.Closing feeder gun trigger starts feeder gun welding and makes both electrodes electrically “HOT”.
2.Pulling SPOOL GUN Trigger:
a.Disables
b.Closing spool gun trigger starts spool gun weld- ing and makes both electrodes electrically “HOT”.
3.Operation with PM 255:
a.Turn the PM 255 input power ON.
b.Adjusting the voltage control will increase or decrease your welding voltage.
c.Adjusting the wire speed control on the spool gun will increase or decrease the spool gun wire feed speed.
4.The following procedure settings for Aluminum 4043 can be used as initial settings for making test
Wire Dia. | WFS Setting | Arc Voltage |
In. (mm) | Spool Gun | Setting |
.030" (.8 mm) | 270 | 15V |
.035" (.9 mm) | 250 | 16V |
3/64" (1.2 mm) | 240 | 20V |
|
|
|
welds to determine final settings:
5.To return to normal PM 255 welding, release the spool gun trigger and reset feeder gun voltage pro- cedure setting if necessary.
6.Operation with Timer Option Kit
All Timer Option Kit functions, except
PM 255