Lincoln Electric PM 255 specifications Installation, Technical Specifications PM

Page 9

 

A-1

 

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – PM 255

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

230/460/575/60 Hz

Duty Cycle 40% 60% 100%

Welding Current Range (Continuous)

30 – 300 Amps

Input Current @ 200 Amp Rated Output

41/20/16 Amps

RATED OUTPUT

Amps

250Amps

200Amps

145Amps

OUTPUT

Maximum Open Circuit Voltage

40 Volts

Input Current @ 250 Amp Rated Output

50/24/19

Volts at Rated Amperes

26Volts

28Volts

26Volts

Welding Voltage Range

10-28 Volts

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

75°C Copper Wire

75°C Copper Wire

 

 

 

Input Ampere

in Conduit

in Conduit

 

Input Voltage/

Fuse or Breaker

Rating On

AWG (IEC) Sizes

AWG (IEC) Sizes

 

 

 

 

(For lengths

(For lengths

 

Frequency (Hz)

Size (Super Lag)

Nameplate

up to 100 ft.)

exceeding 100 ft.)

 

 

 

 

 

 

 

 

 

230/60

60

46

10

(6 mm2)

8

(10 mm2)

 

460/60

30

24

14

(2.5 mm2)

12

(4 mm2)

 

575/60

25

19

14

(2.5 mm2)

12

(4 mm2)

 

NOTE: Use #10 AWG Grounding Wire

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

31.79 in

18.88 in

38.78 in

220 Ibs

808 mm

480 mm

985 mm

100 kg

 

 

 

 

 

WIRE SPEED RANGE

Wire Speed

50 – 700 IPM (1.27 – 17.8 m/minute)

 

 

PM 255

Image 9
Contents RED-D-ARC PM California Proposition 65 Warnings SafetyElectric Shock can kill Iii SafetySûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Master Table of Contents for ALL Sections Master Table of Contents for ALL Sections Technical Specifications PM InstallationInput POWER, Grounding and Connection Diagrams Safety PrecautionsUncrating the PM LocationFigure A.1 Dual Voltage Machine Input Connections Figure A.2 Triple Voltage Machine Input Connections Output Polarity ConnectionsGUN and Cable Installation Shielding GASCylinder may explode if damaged Wear eye, ear and body protec- tion OperationWire Size Conversion Parts Wire Drive RollProduct Description Recommended Processes and EquipmentProcedure for Changing Drive and Idle Roll Sets Wire Reel Loading READI-REELS, Spools or CoilsTo Start the Welder Feeding Wire Electrode Idle Roll Pressure SettingSetting RUN-IN Speed on STAN- Dard Power MIG Feeder Making a Weld Avoiding Wire Feeding ProblemsFAN Control Wire Feed Overload ProtectionInput Line Voltage Protection Welding Thermal Overload ProtectionTimer KIT Installation AccessoriesDrive Roll Kits K363P READI-REEL AdapterOperating Instructions for Timer KIT K1700-1 Included in the K1692-1 Spool GUN Adapter KITMaintenance GUN Handle Disassembly Liner Removal and ReplacementEnglish HOW to USE Troubleshooting Guide TroubleshootingContact your local Authorized Field Service FacilityOutput Problems Contact your local Authorized Field Service Facility GAS Flow ProblemsDiagrams Power MIG 255 230/460/575VDimension Print Page Page Page $700.00 How To Read Shop DrawingsPrecaucion Warnung