Friedrich MW12Y3FM, MW18Y3FM, MW09Y3FM manual Timer Operation

Page 10

TIMER OPERATION

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (P. 4).

To Use the ON timer or OFF timer

1

Press the START/STOP button (Fig. 5 N)

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2

Press the TIMER MODE button (Fig. 5 K) to select the

OFF timer or ON timer operation.

 

Each time the button is pressed the timer function changes in the follow-

 

ing order:

 

 

 

 

 

 

sCANCEL

sOFF

sON

 

 

 

 

 

 

 

 

 

 

PROGRAM(OFF ON, OFF ON) t

 

 

 

 

 

 

The indoor unit’s green TIMER Indicator Lamp (Fig. 3 6) will light.

3

Use the TIMER SET buttons (Fig. 5 K) to adjust the

desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue for about five seconds).

button: Press to advance the time. button: Press to reverse the time.

To Cancel the Timer

Use the TIMER button to select “CANCEL”. The air conditioner will return to normal operation.

To Change the Timer Settings

Perform steps 2 and 3.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

About five seconds later, the entire display will reappear.

To Use the Program timer

1

Press the START/STOP button (Fig. 5 N).

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON timer or OFF timer” to set the desired

 

mode and times.

 

About three seconds later, the entire display will reappear.

 

The indoor unit’s TIMER Indicator Lamp (green) (Fig. 3 6) will light.

3

Press the TIMER MODE button (Fig. 5 K) to select the

PROGRAM timer operation (OFF

 

ON or OFF

 

ON

 

 

 

will display).

 

The display will alternately show “OFF timer” and “ON timer”, then change

 

to show the time setting for the operation to occur first.

 

The program timer will begin operation. (If the ON timer has been se-

 

lected to operate first, the unit will stop operating at this point.)

 

About five seconds later, the entire display will reappear.

About the Program timer

The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

The first timer function to operate will be the one set nearest to the current time.

The order of operation is indicated by the arrow in the Remote Control Unit’s Display (OFF ON, or OFF ON).

One example of Program timer use might be to have the air conditioner auto- matically stop (OFF timer) after you go to sleep, then start (ON timer) automati- cally in the morning before you arise.

To Cancel the Timer

Use the TIMER MODE button to select “CANCEL”.

The air conditioner will return to normal operation.

To Change the Timer Settings

1.Follow the instructions given in the section “To Use the ON Timer or OFF Timer” to se- lect the timer setting you wish to change.

2.Press the TIMER MODE button to select either OFF ON or OFF ON.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reap- pears, then press the appropriate buttons to change the operating condition desired.

En-7

Image 10
Contents Operating Manual Page Operation Timer Super Quiet Coil DRY Contents Safety PrecautionsFeatures and Functions InverterName of Parts Indoor Unit Operating Control Panel Fig Manual Auto buttonPreparation Operation To Stop Operation Press the START/STOP button N About Mode OperationAbout Auto Changeover Operation Timer Operation During Heating operation Sleep Timer OperationAbout the Sleep Timer During Cooling/Dry operationRight-Left Adjustment Adjust the Right-Left louvers Adjusting the Direction of AIR CirculationVertical Air Direction Adjustment Press the SET button O Types of Air flow Direction SettingManual Auto Operation Swing OperationCoil DRY Operation To select Swing Operation Press the Swing button PCleaning and Care Replacing dirty Air cleaning filters Install the Air cleaning filter set setInstall the two Air filters and close the Intake Grille Replace them by two new Air cleaning filtersTroubleshooting Symptom ProblemOperation and Performance Symptom Items to checkOperating Tips Heating PerformanceMulti-type Air conditioner Event of Power InterruptionAuto Restart Simultaneous Use of Multiple UnitsIndoor temperature Temperature and Humidity RangeCooling/Dry Mode Heating Mode Outdoor temperature Indoor Humidity

MW09Y3FM, MW12Y3FM, MW18Y3FM, MR24DY3F, MR36TQY3F, MW12Y3FM, MW09Y3FM, MW18Y3FM specifications

Friedrich is recognized for producing high-performance and reliable air conditioning units, and the models MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F exemplify their commitment to quality.

The MW series, particularly the MW12Y3FM, MW09Y3FM, and MW18Y3FM, offers versatile cooling options suitable for different room sizes. These units come equipped with energy-efficient inverter technology, which adjusts the compressor speed to maintain desired temperatures while reducing energy consumption. This not only helps save on electricity bills but also enhances comfort by minimizing temperature fluctuations.

One of the standout features of these models is their user-friendly Wi-Fi capability, enabling remote control from smartphones and smart home systems. This technology simplifies operation, allowing users to adjust settings, monitor usage, and schedule operations from anywhere. Furthermore, these models include programmable timers and multiple fan settings, providing enhanced flexibility and control over indoor climates.

The MR24DY3F and MR36TQY3F models cater to larger spaces, making them ideal for commercial applications or open-plan areas. Both units feature powerful cooling capacities and are designed to efficiently circulate cool air even in high-demand scenarios. They are also equipped with advanced filtration systems that enhance indoor air quality by capturing dust, allergens, and other particulates.

In terms of durability, Friedrich air conditioners are constructed with high-quality materials, ensuring longevity and resistance to wear and tear. The MW series also indicates quiet operation, with noise-reducing technologies that allow for peaceful environments, whether in homes or workplaces.

Additional characteristics include precise temperature control, an eco-friendly refrigerant, and the ability to run in a dehumidification mode, which is particularly valuable during humid months. The sleek design of these units makes them aesthetically pleasing, allowing them to blend seamlessly into any environment without compromising functionality.

Overall, Friedrich's MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F models represent a blend of innovative technology, efficiency, and performance, making them ideal choices for anyone seeking reliable climate control solutions.