OPERATING TIPS

AUTO Restart

In Event of Power Interruption

The air conditioner power has been interrupted by a power failure. The air conditioner will then restart auto- matically in its previous mode when the power is restored.

Operated by setting before the power failure.

If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this kind of timer fault occurs the TIMER Indicator Lamp will flash (see Page. 3).

Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the Power Supply Plug, reconnect it, and then use the Remote Control Unit to resume operation.

Multi-type Air conditioner

This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.

Simultaneous Use of Multiple Units

When using a multi-type air conditioner, the multiple indoor units can be operated simultaneously, but when two or more indoor units of the same group are oper- ated simultaneously, the heating and cooling efficiency will be less than when a single indoor unit is used alone. Accordingly, when you wish to use more than one in- door unit for cooling at the same time, the use should be concentrated at night and other times when less out- put is required. In the same way, when multiple units are used simultaneously for heating, it is recommended that they be used in conjunction with other auxiliary space heaters, as required.

Seasonal and outdoor temperature conditions, the struc- ture of the rooms and the number of persons present may also result in differences of operating efficiency. We recommend that you try various operating patterns in order to confirm the level of heating and cooling out- put provided by your units, and use the units in the way that best matches your family’s lifestyle.

If you discover that one or more units delivers a low level of cooling or heating during simultaneous opera- tion, we recommend that you stop simultaneous opera- tion of the multiple units.

Operation cannot be done in the following different op- erating modes.

If the indoor unit is instructed to do an operating mode that it cannot perform, the OPERATION indicator lamp (red) on the indoor unit will flash (1 second on, 1 sec- ond off) and the unit will go into the standby mode.

Heating (COIL DRY) mode and cooling mode (or dry mode)

Heating (COIL DRY) mode and fan mode

Operation can be done in the following different operat- ing modes.

Cooling mode and dry mode

Cooling mode and fan mode

Dry mode and fan mode

Heating mode and COIL DRY mode

The operating mode (heating (COIL DRY) mode or cool- ing (dry) mode) of the outdoor unit will be determined by the operating mode of the indoor unit that was oper- ated first. If the indoor unit was started in fan mode, the operating mode of the outdoor unit will not be deter- mined.

For example, if indoor unit (A) was started in fan mode and then indoor unit (B) was then operated in heating mode, indoor unit (A) would temporarily start opera- tion in fan mode but when indoor unit (B) started oper- ating in heating mode, the OPERATION indicator lamp (red) for indoor unit (A) would begin to flash (1 second on, 1 second off) and it would go into standby mode. Indoor unit (B) would continue to operate in heating mode.

Notice

During use of the heating mode, the outdoor unit will occasionally commence the defrost operation for brief periods. During the defrosting operation, if the user sets the indoor unit for heating again, the defrosting mode will continue, and the heating operation will begin after completion of defrosting, with the result that some time may be required before warm air is emitted.

During use of the heating mode, the top of the indoor unit may become warm, but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped; it is not a malfunction.

En-15

Image 18
Contents Operating Manual Page Operation Timer Super Quiet Coil DRY Contents Safety PrecautionsFeatures and Functions InverterName of Parts Indoor Unit Operating Control Panel Fig Manual Auto buttonPreparation Operation About Mode Operation To Stop Operation Press the START/STOP button NAbout Auto Changeover Operation Timer Operation During Heating operation Sleep Timer OperationAbout the Sleep Timer During Cooling/Dry operationRight-Left Adjustment Adjust the Right-Left louvers Adjusting the Direction of AIR CirculationVertical Air Direction Adjustment Press the SET button O Types of Air flow Direction SettingManual Auto Operation Swing OperationCoil DRY Operation To select Swing Operation Press the Swing button PCleaning and Care Replacing dirty Air cleaning filters Install the Air cleaning filter set setInstall the two Air filters and close the Intake Grille Replace them by two new Air cleaning filtersTroubleshooting Symptom ProblemOperation and Performance Symptom Items to checkOperating Tips Heating PerformanceMulti-type Air conditioner Event of Power InterruptionAuto Restart Simultaneous Use of Multiple UnitsIndoor temperature Temperature and Humidity RangeCooling/Dry Mode Heating Mode Outdoor temperature Indoor Humidity

MW09Y3FM, MW12Y3FM, MW18Y3FM, MR24DY3F, MR36TQY3F, MW12Y3FM, MW09Y3FM, MW18Y3FM specifications

Friedrich is recognized for producing high-performance and reliable air conditioning units, and the models MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F exemplify their commitment to quality.

The MW series, particularly the MW12Y3FM, MW09Y3FM, and MW18Y3FM, offers versatile cooling options suitable for different room sizes. These units come equipped with energy-efficient inverter technology, which adjusts the compressor speed to maintain desired temperatures while reducing energy consumption. This not only helps save on electricity bills but also enhances comfort by minimizing temperature fluctuations.

One of the standout features of these models is their user-friendly Wi-Fi capability, enabling remote control from smartphones and smart home systems. This technology simplifies operation, allowing users to adjust settings, monitor usage, and schedule operations from anywhere. Furthermore, these models include programmable timers and multiple fan settings, providing enhanced flexibility and control over indoor climates.

The MR24DY3F and MR36TQY3F models cater to larger spaces, making them ideal for commercial applications or open-plan areas. Both units feature powerful cooling capacities and are designed to efficiently circulate cool air even in high-demand scenarios. They are also equipped with advanced filtration systems that enhance indoor air quality by capturing dust, allergens, and other particulates.

In terms of durability, Friedrich air conditioners are constructed with high-quality materials, ensuring longevity and resistance to wear and tear. The MW series also indicates quiet operation, with noise-reducing technologies that allow for peaceful environments, whether in homes or workplaces.

Additional characteristics include precise temperature control, an eco-friendly refrigerant, and the ability to run in a dehumidification mode, which is particularly valuable during humid months. The sleek design of these units makes them aesthetically pleasing, allowing them to blend seamlessly into any environment without compromising functionality.

Overall, Friedrich's MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F models represent a blend of innovative technology, efficiency, and performance, making them ideal choices for anyone seeking reliable climate control solutions.