Friedrich MW09Y3FM manual To Stop Operation Press the START/STOP button N, About Mode Operation

Page 9

To Stop Operation

Press the START/STOP button (Fig. 5 N).

The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out.

About AUTO CHANGEOVER Operation

AUTO: ● When AUTO CHANGEOVER operation first selected, the fan will oper- ate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.

If the differance between thermostat setting and actual room tempera- ture is more than +4 °F Cooling or dry operation

If the difference between thermostat setting and actual room tempera- ture is within ±4 °F Monitor operation

If the difference between thermostat setting and actual room tempera- ture is more than –4 °F Heating operation

When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room tem- perature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the tem- perature to the value set in the thermostat.

(The monitor operation range is ±4 °F relative to the thermostat set- ting.)

If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, FAN).

About Mode Operation

Heating: ● Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very low fan speed for about 3 to 5 minutes, after which it will switch to the selected fan setting. This period of time is provided to allow the indoor unit to warm up before begin full operation.

When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic Defrosting operation, the OPERATION Indica- tor Lamp (Fig. 3 5) will flash, and the heat operation will be inter- rupted.

Cooling: ● Use to cool your room.

Dry: ● Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when adjusting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan: ● Use to circulate the air throughout your room.

During Heating mode:

Set the thermostat to a temperature set- ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set- ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper- ate).

During Fan mode:

You can not use the unit to heat and cool your room.

En-6

Image 9
Contents Operating Manual Page Operation Timer Super Quiet Coil DRY Safety Precautions ContentsInverter Features and FunctionsIndoor Unit Operating Control Panel Fig Manual Auto button Name of PartsPreparation Operation About Mode Operation To Stop Operation Press the START/STOP button NAbout Auto Changeover Operation Timer Operation About the Sleep Timer Sleep Timer OperationDuring Heating operation During Cooling/Dry operationVertical Air Direction Adjustment Press the SET button O Adjusting the Direction of AIR CirculationRight-Left Adjustment Adjust the Right-Left louvers Types of Air flow Direction SettingCoil DRY Operation Swing OperationManual Auto Operation To select Swing Operation Press the Swing button PCleaning and Care Install the two Air filters and close the Intake Grille Install the Air cleaning filter set setReplacing dirty Air cleaning filters Replace them by two new Air cleaning filtersSymptom Problem TroubleshootingOperating Tips Symptom Items to checkOperation and Performance Heating PerformanceAuto Restart Event of Power InterruptionMulti-type Air conditioner Simultaneous Use of Multiple UnitsCooling/Dry Mode Heating Mode Outdoor temperature Temperature and Humidity RangeIndoor temperature Indoor Humidity

MW09Y3FM, MW12Y3FM, MW18Y3FM, MR24DY3F, MR36TQY3F, MW12Y3FM, MW09Y3FM, MW18Y3FM specifications

Friedrich is recognized for producing high-performance and reliable air conditioning units, and the models MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F exemplify their commitment to quality.

The MW series, particularly the MW12Y3FM, MW09Y3FM, and MW18Y3FM, offers versatile cooling options suitable for different room sizes. These units come equipped with energy-efficient inverter technology, which adjusts the compressor speed to maintain desired temperatures while reducing energy consumption. This not only helps save on electricity bills but also enhances comfort by minimizing temperature fluctuations.

One of the standout features of these models is their user-friendly Wi-Fi capability, enabling remote control from smartphones and smart home systems. This technology simplifies operation, allowing users to adjust settings, monitor usage, and schedule operations from anywhere. Furthermore, these models include programmable timers and multiple fan settings, providing enhanced flexibility and control over indoor climates.

The MR24DY3F and MR36TQY3F models cater to larger spaces, making them ideal for commercial applications or open-plan areas. Both units feature powerful cooling capacities and are designed to efficiently circulate cool air even in high-demand scenarios. They are also equipped with advanced filtration systems that enhance indoor air quality by capturing dust, allergens, and other particulates.

In terms of durability, Friedrich air conditioners are constructed with high-quality materials, ensuring longevity and resistance to wear and tear. The MW series also indicates quiet operation, with noise-reducing technologies that allow for peaceful environments, whether in homes or workplaces.

Additional characteristics include precise temperature control, an eco-friendly refrigerant, and the ability to run in a dehumidification mode, which is particularly valuable during humid months. The sleek design of these units makes them aesthetically pleasing, allowing them to blend seamlessly into any environment without compromising functionality.

Overall, Friedrich's MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F models represent a blend of innovative technology, efficiency, and performance, making them ideal choices for anyone seeking reliable climate control solutions.