Friedrich MW09Y3FM, MW18Y3FM manual Operating Tips, Operation and Performance, Heating Performance

Page 17

TROUBLESHOOTING

 

Symptom

Problem

See Page

 

 

 

 

NORMAL

Airflow is weak or stops:

● In case of Multi-type unit, if multiple units are operated in differ-

 

FUNCTION

 

ent operation modes as shown below, the units operated after-

 

 

 

ward will stop and the OPERATION indicator lamp (red) will flash.

15

 

 

Heating mode and cooling mode (or dry mode)

 

 

 

Heating mode and fan mode

 

 

 

 

 

 

Water is produced from

● During Heating operation, water may be produced from the out-

14

 

the outdoor unit:

door unit due to the Automatic Defrosting operation.

 

 

 

 

 

 

 

Symptom

Items to check

See Page

 

 

 

 

CHECK ONCE

Doesn’t operate at all:

● Is the Power Supply Plug disconnected its outlet?

 

MORE

 

● Has there been a power failure?

 

 

 

 

● Has a fuse blown out, or a circuit breaker been tripped?

 

 

 

 

 

 

 

● Is the timer operating?

7 - 8

 

 

 

 

 

Poor Cooling performance:

● Is the Air Filter dirty?

 

 

 

● Air the air conditioner’s intake grille or outlet port blocked?

 

 

 

● Did you adjust the room temperature settings (thermostat) cor-

 

 

 

rectly?

 

 

 

● Is there a window or door open?

 

 

● In the case of Cooling operation, is a window allowing bright sun-

 

 

 

light to enter? (Close the curtains.)

 

 

 

● In the case of Cooling operation, are there heating apparatus and

 

 

 

computers inside the room, or are there too many people in the

 

 

 

room?

 

 

 

 

 

 

 

● Is the unit set for SUPER QUIET operation?

5

 

 

 

 

 

The unit operates

● Are the Remote Control Unit’s batteries dead?

 

 

differently from the Remote

● Are the Remote Control Unit’s batteries loaded properly?

4

 

Control Unit’s setting:

 

 

 

 

 

 

 

 

If the problem persists after performing these checks, or if you notice burning smells, or the TIMER Indicator Lamp (Fig. 3 6) and OPERATION Indicator Lamp (Fig. 3 5) flashes, immediately stop operation, disconnect the Power Supply Plug, and con- sult authorized service personnel.

OPERATING TIPS

Operation and Performance

Heating Performance

Microcomputer-controlled Automatic Defrosting

This air conditioner operates on the heat-pump princi- ple, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating performance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con- ditioner until the room is heated.

When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating per- formance.

In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Auto- matic Defrosting function. If frost forms, the air condi- tioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7-15 minutes).

During Automatic Defrosting operation, the OPERATION Indicator Lamp (red) will flash.

En-14

Image 17
Contents Operating Manual Page Operation Timer Super Quiet Coil DRY Safety Precautions ContentsInverter Features and FunctionsIndoor Unit Operating Control Panel Fig Manual Auto button Name of PartsPreparation Operation About Auto Changeover Operation About Mode OperationTo Stop Operation Press the START/STOP button N Timer Operation About the Sleep Timer Sleep Timer OperationDuring Heating operation During Cooling/Dry operationVertical Air Direction Adjustment Press the SET button O Adjusting the Direction of AIR CirculationRight-Left Adjustment Adjust the Right-Left louvers Types of Air flow Direction SettingCoil DRY Operation Swing OperationManual Auto Operation To select Swing Operation Press the Swing button PCleaning and Care Install the two Air filters and close the Intake Grille Install the Air cleaning filter set setReplacing dirty Air cleaning filters Replace them by two new Air cleaning filtersSymptom Problem TroubleshootingOperating Tips Symptom Items to checkOperation and Performance Heating PerformanceAuto Restart Event of Power InterruptionMulti-type Air conditioner Simultaneous Use of Multiple UnitsCooling/Dry Mode Heating Mode Outdoor temperature Temperature and Humidity RangeIndoor temperature Indoor Humidity

MW09Y3FM, MW12Y3FM, MW18Y3FM, MR24DY3F, MR36TQY3F, MW12Y3FM, MW09Y3FM, MW18Y3FM specifications

Friedrich is recognized for producing high-performance and reliable air conditioning units, and the models MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F exemplify their commitment to quality.

The MW series, particularly the MW12Y3FM, MW09Y3FM, and MW18Y3FM, offers versatile cooling options suitable for different room sizes. These units come equipped with energy-efficient inverter technology, which adjusts the compressor speed to maintain desired temperatures while reducing energy consumption. This not only helps save on electricity bills but also enhances comfort by minimizing temperature fluctuations.

One of the standout features of these models is their user-friendly Wi-Fi capability, enabling remote control from smartphones and smart home systems. This technology simplifies operation, allowing users to adjust settings, monitor usage, and schedule operations from anywhere. Furthermore, these models include programmable timers and multiple fan settings, providing enhanced flexibility and control over indoor climates.

The MR24DY3F and MR36TQY3F models cater to larger spaces, making them ideal for commercial applications or open-plan areas. Both units feature powerful cooling capacities and are designed to efficiently circulate cool air even in high-demand scenarios. They are also equipped with advanced filtration systems that enhance indoor air quality by capturing dust, allergens, and other particulates.

In terms of durability, Friedrich air conditioners are constructed with high-quality materials, ensuring longevity and resistance to wear and tear. The MW series also indicates quiet operation, with noise-reducing technologies that allow for peaceful environments, whether in homes or workplaces.

Additional characteristics include precise temperature control, an eco-friendly refrigerant, and the ability to run in a dehumidification mode, which is particularly valuable during humid months. The sleek design of these units makes them aesthetically pleasing, allowing them to blend seamlessly into any environment without compromising functionality.

Overall, Friedrich's MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F models represent a blend of innovative technology, efficiency, and performance, making them ideal choices for anyone seeking reliable climate control solutions.