Lincoln Electric IM679-A manual Welding Process Modes Availiable, Electrode Material

Page 16

B-5

 

OPERATION

 

B-5

 

 

 

 

 

CONTROLS: (See Figure 2)

The MEMORY button and SELECT knob are used together to select a welding process an store it in (M1 thru M8). The SELECT knob scrolls through the, welding process modes and memory modes M1 thru M8. The MEMORY button stores the welding process in memory.

SELECT button" (The right button) selects between the "Hot Start" or "Arc Control". The < will indicate the active feature shown below.

Right Digital Window "Hot Start" (-10 to 0 +10) "Arc Control" (0 to 10) <

The ADJUST knob adjusts the desired settings for the Hot Start or Arc Control feature that is active.

WELDING PROCESS MODES AVAILIABLE

Stick SMAW, TIG GTAW

Gouge CAG, CV MIG GMAW

CV Flux Core, Pulse MIG

ELECTRODE MATERIAL

Steel, Metal Core, Stainless, Aluminum, Nickel

EXAMPLE OF SAVING WELDING MODES TO MEMORY

The following example is how to select Pulse MIG using .035 steel and store it into memory.

1.Turn the Select knob until welding process is dis- played.

RIGHT WINDOW

LEFT WINDOW

Pulse MIG

Argon Blends

Steel .035

 

2.Wait two seconds and the right window will display Arc Control on the second line on the right side.

Pulse MIG

Argon Blends

Steel .035

Arc Cntrl ### <

3.SPd is displayed in the upper right Volts window. The left Amps window matches the desired wire feed speed that is set on the wire feeder. Adjust the Output knob until desired number is displayed.

4.Start welding. If the arc length is too short turn the Output knob up. If the arc length is too long turn the Output knob down.

The Arc Control which is displayed in the right digital window can be used to fine-tune the arc length and characteristics.

5.After all adjustments have been made press and hold the Memory button until the display changes. The right and the left window will display what memory to save in, lets say M1. To store in M1 push the Memory button again to save the Pulse Mig mode to memory M1.

6.The display in the digital windows read as follows:

M1 Pulse MIG

Argon Blends

Steel .035

Arc Cntrl 1.2

7.Saving or entering a second welding mode to a memory, M2. Turn the Select knob until the desired welding process mode is displayed in right digital window. Then follow steps 1 thru 6.

Press the Memory button till the digital window reads,

Save to MEM M2

Press the Memory button again and the New Welding process is saved in M2.

8.Adjust the output control to the correct wire feed setting and the V350-PRO is ready to weld again. (Note: The wire feed speed setting is not stored in memory and will need to be reset.)

9.Adjust the Arc Control and note that the M1 goes away indicating that the V350-PRO settings no longer match what is stored in memory. Going back to the original settings will not bring the M1 back. You will need to push the Memory button to recall the original settings in M1.

Note: After all memorys M1 thru M8 are used and the welder needs to store another welding process, a new welding process will overwrite what was originally in the memory and will read,

Save to MEM M1 Overwrite

M1 which stored Pulse Mig is Overwritten with the new welding process.

V350-PRO

Image 16
Contents Invertec V350-PRO Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Thank You Table of Contents Installation V350-PROConnections of Wire Feeders to V350-PRO Safety PrecautionsSelect Suitable Location Remote Control of Invertec Undercarriage MountingsParallel Operation Quick Disconnect PlugsOperation Duty CycleVolt Meter Output ControlThermal Weld Mode Select Factory and Construction See FigureCONTROL-REMOTE / Local Operation 7A. Advanced Process Panel Electrode Material Welding Process Modes AvailiableExample of Saving Welding Modes to Memory Weld Mode Details Gmaw CVLN-10/DH-10 Wire Feeder Compatibility Note Pulse ProgramsLower Case Panel Weld TerminalsDesign Features and Advantages Auxiliary PowerLimitations Recommended ProcessesAccessories Options / Accessories Construction Version K1728-2Field Installed Options Advanced Process Version K1728-4Maintenance Capacitor Discharge ProcedureRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideSymptoms Authorized Field ServicePossible Areas Contact your Local LincolnContact your local Lincoln Authorized Field Service Facility CPU Displays Description Scrolling dash Diagrams Remote Control AdaptersK867 Plug to LN-7 Connection Diagram K867 Plug to LN-25 Connection Diagram K867 Universal Adapter / Invertec Connection Diagram K876 Adapter to LN-25 Connection Diagram K864 Adapter to LN-7 & Remote Control Connection Diagram Wiring Diagram Invertec V350-PRO Dimension Print V350-PRO V350-PRO Precaucion Warnung