B-8

 

OPERATION

 

B-8

 

 

 

 

 

LOWER CASE PANEL

The output studs, line switch and remote connector are located on the lower case front.

9. Both STUDS contain "Twist-Mate" connector inserts.

The Negative stud is configured to accept the pass through gas system.

10. The ON-OFF switch is a 3-phase circuit breaker rated at 100 amps per leg.

11.The METER POLARITY switch is located above the output connectors. The switch provides a work connection for wire feeder voltmeters. Place the switch in the position of the electrode polarity indi- cated by the decal. The switch does not change the welding polarity.

12.6-PIN MS-style connectors for remote control.

REMOTE CONTROL of the OUTPUT CONTROL and

WELD TERMINALS

The Invertec V350-Pro has auto sensing of remote output controls.If after connecting or removing a remote, the Invertec V350-Pro did not configured the way you would like the local or remote control settings can be changed by pushing the OUTPUT CONTROL or WELD TERMINAL button. (A user cannot select between the 6 and 14 pin MS-style connectors.)

CV modes

The remote will default to the 14-pin MS-style con- nectors remote if a remote is connected to either of the 14-pin MS-style connectors and the 6-pin MS- style connectors. Note: Only one of the 14-pin MS- style connectors can have a remote control connect- ed at a time. If no remote is connected to either of the 14-pin MS-style connectors then the remote will default to the 6-pin MS-style connectors if a remote is connected to it.

In all of the CV modes, the WELD TERMINAL con- trol will default to REMOTE.

TIG mode

The remote will default to the 6-pin MS-style if a remote control is connected to the 6-pin MS-style and one of the 14-pin MS-style connectors. If a remote is not connected to the 6-pin MS-style con- nector then the remote will default to the 14-pin MS- style connector if a remote is connected to one of the 14-pin MS-style connector.

If a remote control is connected to any of the ms- style s the WELD TERMINAL control will default to REMOTE. If there are not any remote control devices attached the WELD TERMINAL control will default to ON.

CC-Stick modes

The remote will default to only the 6-pin MS-style connector if a remote is connected to it.

The WELD TERMINAL control will default to ON with or without a remote connected.

Types of Remote OUTPUT CONTROL

The Invertec V350-Pros Output Control can be con- trolled by either a potentiometer connected between 77 & 75 with the wiper connected to 76 or a 0V to 10V DC supply connected between 76 & 75. (76 needs to be positive)

14-Pin Ms-style connector lead 75 is pin G, lead 76 is pin F and lead 77 is pin E.

6-Pin Ms-style connector lead 75 is pin C, lead 76 is pin B and lead 77 is pin A.

Potentiometer Control

The total resistance should be between 2000 ohms (2K) and 10,000 ohms (10K)

The machine output will be at minimum when lead 76 (wiper) is at the end of the potentiometer that is connected to 75. The machines output will increase as the wiper of the potentiometer is moved to the end that is connected to 77. (Note: In TIG mode, moving the lead 76 (wiper) to lead 77 would pro- duce the current that has been set by the Invertec V350-Pros front panel Output Control.)

Remotes of this type offered by Lincoln Electric are the K857, K812 and K870.

Voltage Control

The supply should be an isolated supply. (Not refer- enced to earth ground, any auxiliary power from the Invertec V350-Pro or the welding output) The supply should be capable of supplying at least 20mA.

0 volts supplied to 76 will set the Invertec V350-Pro to minimum output for the mode that has been selected while 10 volts supplied to 76 will set the Invertec V350-Pro to the maximum output for the mode. (Note: In TIG mode, 10 volts supplied to lead 76 would produce the current that has been set by the Invertec V350-Pros front panel Output Control.)

Types of Remote WELD TERMINAL Control

The Invertec V350-Pros Weld Terminals can be controlled from each of the MS-style connectors. The circuit has a nominal OCV of 15VDC and requires a dry contact closure (less than 100 ohms) to activate the output of the Invertec V350-Pro.

14-Pin MS-style connectors, the Weld Terminals are controlled from pins C (lead 2) and pin D (lead 4). Pin C is positive.

6-Pin MS-style connectors, the Weld Terminals are controlled from pin D (lead 2) and pin E (lead 4). In the 6-pin ms-style connectors pin D is positive.

V350-PRO

Image 19
Contents Invertec V350-PRO California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionPrécautions DE Sûreté Thank You Table of Contents V350-PRO InstallationConnections of Wire Feeders to V350-PRO Safety PrecautionsSelect Suitable Location Undercarriage Mountings Remote Control of InvertecQuick Disconnect Plugs Parallel OperationOutput Control OperationDuty Cycle Volt MeterThermal Weld Mode Select Factory and Construction See FigureCONTROL-REMOTE / Local Operation 7A. Advanced Process Panel Electrode Material Welding Process Modes AvailiableExample of Saving Welding Modes to Memory Gmaw CV Weld Mode DetailsPulse Programs LN-10/DH-10 Wire Feeder Compatibility NoteWeld Terminals Lower Case PanelRecommended Processes Design Features and AdvantagesAuxiliary Power LimitationsAdvanced Process Version K1728-4 AccessoriesOptions / Accessories Construction Version K1728-2 Field Installed OptionsPeriodic Maintenance MaintenanceCapacitor Discharge Procedure Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your Local Lincoln SymptomsAuthorized Field Service Possible AreasContact your local Lincoln Authorized Field Service Facility CPU Displays Description Scrolling dash Remote Control Adapters DiagramsK867 Plug to LN-7 Connection Diagram K867 Plug to LN-25 Connection Diagram K867 Universal Adapter / Invertec Connection Diagram K876 Adapter to LN-25 Connection Diagram K864 Adapter to LN-7 & Remote Control Connection Diagram Wiring Diagram Invertec V350-PRO Dimension Print V350-PRO V350-PRO Precaucion Warnung