Lincoln Electric IM311-E manual Instructions for Loading Wire Into LN-23P

Page 12

B-2

OPERATION

B-2

 

 

 

INSTRUCTIONS FOR LOADING WIRE INTO LN™-23P

(For machines that have code numbers Higher than 11384.)

1.With the power shut off and input leads going to the wire feeder disconnected, lay LN™-23P down with wire reel facing up.

2.Remove compartment cover along with plastic wire reel brake and reel cover. Pull wire end from spool and route it through the liner opening that is mount- ed inside the wire reel case.

 

 

Feed Wire thru

Reel Cover

 

Liner Opening.

 

 

 

3.Pull 2-3 ft. of wire through upper conduit cable piece as shown in picture below.

4.Add Reel Cover. Form a loop with the wire and route it through the lower conduit piece and past the drive rolls as shown below .

Feed into Drive

Rolls in this area.

Loop

Enter Wire thru conduit piece

Add Reel Cover

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically hot parts.

5.Turn on power and trigger the gun to take up slack in the wire.

Watch for kinks when feeding wire thru conduit.

6.Connect the upper conduit and lower Conduit pieces as shown in picture below.

2-3 Feet

Upper and Lower conduit.

LN™-23P

Image 12
Contents LN -23P Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications LN-23PEnvironmental Rating Safety Precautions Input CableWork Cable and Remote Voltage Sensing Work Lead Wire Drive Rolls and Guide Tubes Optional Features InstallationInnershield GUN and Cable Loading the Wire Reel OperationProduct Description Instructions for Loading Wire Into LN-23P For machines that have code numbers Higher thanAdjusting Wire Feed Speed and Voltage Drive Roll PressureMaking the Weld Accessories Enclosed Wire Reel SupportOptional Equipment GUN and Cable AssembliesMaintenance Removing Idle Roll AssemblyGUN and Cable Maintenance Wire Drive Assembly MaintenancePower Source Circuit Protection NameplatesTroubleshooting HOW to USE Troubleshooting GuideContact your local Lincoln Authorized Field Service Facility Troubleshooting Diagrams LN-23P Adapter KIT Wiring DiagramWiring Diagram LN-23P Wiring Diagram Connection of CV Converter to LN-23P’S and SA-200 or SA-250 14269 Connection of LN-23P and Adapter KIT to R3S-250 or R3S-325 Connection of LN-23P and Adapter KIT to R3S-400, 600 or 14272 Diagrams Diagrams Diagrams 12DIAGRAMS 17124 2-19-82MField Calibration of K-316 LN-23P P.C. Board Precaucion Warnung