Lincoln Electric DC-400 manual Safety

Page 2

i

SAFETY

i

WARNING

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents are known to the State of California to cause can- cer, birth defects, and other reproductive harm.

The Above For Diesel Engines

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

The Above For Gasoline Engines

ARC WELDING CAN bE HAzARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIbLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR bEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

bE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY bY QUALIFIED INDIVIDUALS.

FOR ENGINE powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz- ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.

1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.

ELECTRIC AND MAGNETIC FIELDS may be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.

2.c. Exposure to EMF fields in welding may have other health effects which are now not known.

2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.

2.d.5. Do not work next to welding power source.

Image 2
Contents Safety Depends on You Idealarc DC-400Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Technical Specifications DC-400 FALLING EQUIPMENT can cause Safety PrecautionsInput Power Connections Correct Operational USEOutput Cables Installation of Field Installed OptionsOutput Cable Connections Remote Output Control K857 or K857-1 with K864 AdapterK843 Amptrol Adapter Installation Instructions K870 AmptrolDesign Multiprocess Switch Connection and Operation PurposeConnection of DC-400 to LN-22 or LN-25 ConnectionsMultiprocess Switch STICK, TIG or AIR/CARbON ARCSafety Precautions ELECTRIC SHOCK can killVoltmeter Switch Output Terminals Switch Rating PlateMode Switch ARC Force Control DialNEMA EW 1 IEC 60974-1 Rating PlateRecommended Processes & Equipment Operational Features & ControlsGeneral Machine Description Power Source Operation and Controls Duty Cycle and Time PeriodOUTPUT TERMINALS SWITCH ARC FORCE CONTROL Dial Effective only in CC modeARC CONTROL SWITCH Effective only in CV FCAW/GMAW mode Front View of 14-PIN Connector ReceptacleTerminal Strip Connections Machine and Circuit ProtectionCase Features Auxiliary Power ConnectionsRemote Control Connections Output ConnectionsMachine & Circuit Protection Thermal Protection Light Optional Equipment Factory Installed OptionsField Installed Options TIG OptionsK799 Codes 8634 and AbOVE only Amptrol ADAPTER CAbLE K843HI-FREQUENCY KIT Undercarriages K817, K817R, K817P K8411MAINTENANCED-1 Routine MaintenanceTROUbLESHOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionOutput Control Local TROUbLESHOOTING TROUbLESHOOTING Power I/0 Switch Check Connecting the Remote Control to the MachineFault Protection Operation Output VoltageCHECKING PROCEDURE Power Diode TestPower RECTIFIER bRIDGE ASSEMbLY Power Silicon Controlled Rectifier TestDiagrams Code is pasted inside Number 400 Wiring Diagram for Codes 10859, 10880,11083Idealarc DC Wiring Idealarc DC-400 Diagram for Code 9847Code is pasted inside Number Idealarc DC-400 Idealarc DC-400 Precaucion Warnung
Related manuals
Manual 42 pages 56.14 Kb

DC-400 specifications

The Lincoln Electric DC-400 is a versatile and robust DC arc welding power source designed to meet the demands of various industrial applications. Known for its reliability and performance, the DC-400 is ideal for both professional welders and fabrication shops requiring robust equipment that can handle challenging welding tasks.

One of the main features of the DC-400 is its ability to provide a smooth, stable arc, which is essential for achieving high-quality welds. This welding machine is capable of delivering a wide amperage range, typically from 20 to 400 amperes, making it suitable for various welding processes, including MIG, TIG, and Stick welding. The unit's high output capabilities allow it to effectively weld a variety of materials, such as steel, stainless steel, and various alloys.

In terms of technology, the DC-400 integrates advanced power conversion technology that enhances energy efficiency while minimizing heat loss during operation. This not only contributes to lower operating costs but also ensures a longer service life for the machine. The DC-400 features a durable, rugged design, with a robust steel frame that can withstand the rigors of heavy industrial use while providing an IP23 rating for protection against moisture and dust.

Another notable characteristic of the DC-400 is its ease of use. The intuitive controls allow for quick adjustments to settings, enabling welders to easily adapt to different job requirements. The arc characteristics of the DC-400 can be fine-tuned to optimize performance for different welding applications, ensuring consistent results every time.

Moreover, the DC-400 is equipped with built-in safety features such as thermal overload protection, which prevents damage to the machine in case of prolonged operation under heavy loads. This feature enhances the safety of the operator and extends the life of the welding machine.

Overall, the Lincoln Electric DC-400 stands out as a reliable and efficient welding power source. Its combination of high-performance capabilities, advanced technology, and next-level usability makes it a popular choice in the industry. Whether for heavy fabrication, maintenance, or repair work, the DC-400 continues to prove itself as an indispensable tool for professional welders seeking quality and durability in their equipment.