TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
OUTPUT control not functioning on | 1. OUTPUT CONTROL switch in |
| ||
“REMOTE” control. |
| wrong position. Place switch in |
| |
|
| “REMOTE”. |
| |
| 2. | Faulty OUTPUT CONTROL |
| |
|
| switch. |
| |
| 3. | Faulty remote control potentiome- |
| |
|
| ter. |
| |
| 4. | Leads or connections open in |
| |
|
| control circuit. |
| |
| 5. | Faulty Control PC Board. |
| |
|
|
|
| |
Poor arc striking with semiautomat- | 1. | Defective start circuit. |
| |
ic or automatic wire feeders. | 2. | Poor work connection. | If all recommended possible areas of | |
| 3. | Improper procedures. | misadjustment have been checked | |
| 4. | Defective Control PC Board. | and the problem persists, Contact | |
|
|
| your local Authorized Field | |
Poor arc characteristics. | 1. | Start circuit energized at all times | ||
Service Facility. | ||||
|
| (read switch CR3 not closing). |
| |
| 2. | Defective Start PC Board. |
| |
| 3. | Defective Control PC Board. |
| |
| 4. | Capacitor(s) in output circuit |
| |
|
| failed. A failure is indicated if the |
| |
|
| small vent plug on top of a capac- |
| |
|
| itor is raised or blown out. |
| |
|
|
| ||
ARC CONTROL has no effect in | 1. Defective R1, L1, S4C, S4D actu- |
| ||
CV (FCAW/GMAW) mode with |
| ator or S5. |
| |
short circuit transfer processes. |
|
|
| |
|
|
| ||
115VAC Receptacle not working. | 1. Circuit Breaker Tripped. |
| ||
| 2. | Defective Circuit Breaker. |
| |
| 3. | Broken Connection in Wiring. |
| |
|
|
|
| |
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.