Lincoln Electric DC-400 specifications 11085, 11128

Page 36

 

 

F-3

DC-400

WIRING DIAGRAM FOR CODES 11038,

DIAGRAMS

 

11085, 11128, 11347

 

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside

F-3

the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number..

 

Image 36
Contents RED-D-ARC DC-400 10699 11038 11085 11128 11347Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Vii Section DSection E Installation Technical Specifications DC-400Output Maximum Open Circuit Voltage Auxiliary Power Height Width Depth WeightMachine Load Cable400A 100% 500A 50% Duty Lengths CycleRemote Control Adapter Cable K864 Multiprocess Switch K804-1 Multiprocess Switch Connection and Operation Purpose Connection of DC-400 to LN-22 or LN-25Design OperationAuxiliary Power Connections Remote Control ConnectionsCase Features Output ConnectionsMachine & Circuit Protection Thermal Protection Light Multiprocess Switch STICK, TIG or AIR/CARBON ARCOperation Electric Shock can killARC Control Switch Output Terminals SwitchVoltmeter Switch Rating Plate ARC Force Control DialIP21 Degree of protection provided by the enclosure4OPERATIONB-4 Earth Ground ConnectionSignifying the Earth Ground Connection DC-400 Recommended Processes & Equipment Power Source Operation Voltmeter SwitchDuty Cycle and Time Period Duty Cycle Amps VoltsARC Force Control Dial Effective only in CC mode ARC Control Switch Effective only in CV FCAW/GMAW modeFront View of 14-PIN Connector Receptacle PIN Lead no FunctionTerminal Strip Connections Machine and Circuit ProtectionAccessories Factory Installed OptionsField Installed Options HI-FREQUENCY KIT K799 Codes 8634 and Above only Undercarriages K817, K817R, K8411MAINTENANCED-1 Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideContact your local Authorized Field Service Facility Output Control Local Service Facility Your local Authorized FieldProcedure for Replacing PC Boards Connecting the Remote Control to the MachineFault Protection Operation Power I/0 Switch Check Remote Control Check Power Diode Test Power Rectifier Bridge Assembly Checking Procedure Power Silicon Controlled Rectifier TestDiagrams Wiring Diagram for CodeWiring Diagram for Code 10699 and Above Pasted inside Number11085, 11128 Power Rectifier Bridge Diagram Dimension Print Type M12244-7 DC-400 32.00 15.39 30.92 30.02 +.11DC-400 Precaucion Warnung
Related manuals
Manual 42 pages 48.7 Kb