Lincoln Electric Installation, Technical Specifications DC-400, Height Width Depth Weight

Page 9

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS – DC-400

 

INPUT-THREE PHASE ONLY

 

Standard

 

Input Current at Rated Output (CVI)

Voltage

100% Duty Cycle

60% Duty Cycle(4)

50% Duty Cycle

Frequency

 

 

 

230/460/575V/60Hz

400Amps/36V

450Amps/38V

500Amps/40V

 

78/39/31Amps

83/42/33Amps

84/42/34Amps

RATED OUTPUT

Duty Cycle (1)

Amps

Volts at Rated Amps

100%

400

36

60%

450

38

50%

500

40

 

 

 

OUTPUT

 

 

 

OUTPUT

MAXIMUM OPEN CIRCUIT VOLTAGE

AUXILIARY POWER

 

 

 

Min.----60A 12V CV(22V CC)

57V. (CC) 45.5V. (CVI)

115 VAC, 15 AMPS

Max.---500A 42V (CC, CV)

 

42 VAC, 10 AMPS

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

INPUT

INPUT AMPERE

TYPE 75°C COPPER

TYPE 75°C GROUND

TYPE 75°C

VOLTAGE /

RATING ON

WIRE IN CONDUIT

WIRE IN CONDUIT

SUPER LAG

FREQUENCY

NAMEPLATE

AWG (IEC)

AWG (IEC)

OR BREAKER

 

@ 100%

SIZES (mm2)

SIZES (mm2)

SIZE(AMPS)

 

Duty Cycle

40°C(104°F)

 

 

 

 

 

 

 

230/60HZ

78

3(25)

6(10)

125

460/60HZ

39

8(10)

10(6)

60

575/60HZ

31

10(6)

10(6)

50

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

HEIGHT

WIDTH

DEPTH

WEIGHT

27.50 in.

22.25 in.

32.0 in.

473 lbs.

699 mm

565 mm

988 mm

215 kg.

 

 

 

 

 

 

 

 

(1) Based upon 10 minute time period (i.e., for 60% duty cycle, it is 6 minutes on an 4 minutes off).

DC-400

Image 9
Contents 10699 11038 11085 11128 11347 RED-D-ARC DC-400California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE Sûreté On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Vii Section DSection E Technical Specifications DC-400 InstallationOutput Maximum Open Circuit Voltage Auxiliary Power Height Width Depth WeightCable Machine Load400A 100% 500A 50% Duty Lengths CycleRemote Control Adapter Cable K864 Multiprocess Switch K804-1 Connection of DC-400 to LN-22 or LN-25 Multiprocess Switch Connection and Operation PurposeDesign OperationRemote Control Connections Auxiliary Power ConnectionsCase Features Output ConnectionsMachine & Circuit Protection Thermal Protection Light STICK, TIG or AIR/CARBON ARC Multiprocess SwitchElectric Shock can kill OperationOutput Terminals Switch ARC Control SwitchVoltmeter Switch Rating Plate ARC Force Control DialDegree of protection provided by the enclosure IP214OPERATIONB-4 Earth Ground ConnectionSignifying the Earth Ground Connection DC-400 Recommended Processes & Equipment Voltmeter Switch Power Source OperationDuty Cycle and Time Period Duty Cycle Amps VoltsARC Control Switch Effective only in CV FCAW/GMAW mode ARC Force Control Dial Effective only in CC modeFront View of 14-PIN Connector Receptacle PIN Lead no FunctionMachine and Circuit Protection Terminal Strip ConnectionsAccessories Factory Installed OptionsField Installed Options Undercarriages K817, K817R, K841 HI-FREQUENCY KIT K799 Codes 8634 and Above onlyRoutine Maintenance 1MAINTENANCED-1HOW to USE Troubleshooting Guide TroubleshootingContact your local Authorized Field Service Facility Output Control Local Your local Authorized Field Service FacilityConnecting the Remote Control to the Machine Procedure for Replacing PC BoardsFault Protection Operation Power I/0 Switch CheckPower Diode Test Remote Control CheckPower Rectifier Bridge Assembly Checking Procedure Power Silicon Controlled Rectifier TestWiring Diagram for Code DiagramsPasted inside Number Wiring Diagram for Code 10699 and Above11085, 11128 Power Rectifier Bridge Diagram Type M12244-7 DC-400 32.00 15.39 30.92 30.02 +.11 Dimension PrintDC-400 Precaucion Warnung