Lincoln Electric IM665 manual Troubleshooting

Page 21

E-2

TROUBLESHOOTING

E-2

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

Input circuit breaker trips repeated. 1. This may be normal. If output is set to maximum a 30 amp circuit is required. See Technical Specification page.

2.Install a larger input circuit or turn the output control to a lower amperage.

No Status indicators light and the fan 1. Check the input power to be sure does not operate 5 seconds after the it is on.

power switch is turned on.

2.Check the power line fuses and machine connection.

3.Disconnect input power at fuse panel and check line switch conti- nuity. Replace line switch if bad.

4.Check the fuses on the input board.

 

 

If all recommended possible areas of

 

 

misadjustment have been checked

No Status indicators light 5 seconds 1. Disconnect input power from the and the problem persists, Contact

after the power switch is turned on,

machine. Check that connectors your local Lincoln Authorized

but the fan operates.

on harness between Control Bd. Field Service Facility.

 

and Power Bd. are properly seat-

 

ed.

2.Possible faulty Control Board.

3.Possible faulty Power Board.

The Thermal LED does not go out. 1. Check consumables - The safety light lights when an unsafe condi- tion exists either at the torch or somewhere else within the sys- tem.

2.Possible faulty Power board.

3.Possible faulty Control board.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

PRO-CUT 25

Image 21
Contents PRO-CUT TM Electric Shock can kill SafetyPlasma ARC can injure Page Sûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Table of Contents Technical Specifications PRO-CUT 25 K1756-1 InstallationSelect Proper Location Safety Precautions Electric Shock can KillHigh Frequency Interference Protection Input Electrical ConnectionsGAS Input Connections Torch Output ConnectionsPreheat Temperature for Plasma Cutting Safety PrecautionsOperation DescriptionOperational Features and Controls Design Features AdvantagesUser Responsibility Consumable Life Cutting CapabilityLimitations Controls and SettingsElectric Shock can Kill Pilot ARC DiscussionGeneral In All Cases Procedure RecommendationsGeneral Options Accessories AccessoriesMaintenance Routine MaintenancePeriodic Maintenance HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Problems Or dross Symptom Check SW1 PRO-CUT 25 Wiring DiagramPrecaucion Warnung
Related manuals
Manual 29 pages 20.43 Kb