Lincoln Electric IM665 manual Installation, Technical Specifications PRO-CUT 25 K1756-1

Page 8

 

A-1

INSTALLATION

A-1

 

TECHNICAL SPECIFICATIONS - PRO-CUT 25 (K1756-1)

 

 

 

 

 

 

 

 

 

 

INPUT - SINGLE PHASE / 60 HERTZ ONLY

 

 

 

 

Standard Voltage

1Ø Input Current at Rated Output

 

 

 

 

115/230/1/50/60Hz

115 V : 15 A @ 20%

 

 

 

 

 

115 V : 26.7A@ 60%

 

 

 

 

 

115 V : 37.7A@ 35%

 

 

 

 

 

230 V : 15 A@100%

 

 

 

 

 

230 V : 19 A @ 60%

 

 

 

 

 

 

 

 

RATED OUTPUT

Duty Cycle

AMPS

20% on 115 V

15 A

60% on 115 V

20 A

100% on 230 V

20 A

35% on 115 V

25 A

60% on 230 V

25 A

 

 

Current

Range

12-25 Amps

OUTPUT

Open Circuit

Voltage

400 VDC

Pilot Current

12 Amps

REQUIRED GAS FLOW RATE

55 PSI @ 240 SCFH

( 3.8 Bar. @ 6800 LHR)

REQUIRED GAS INLET PRESSURE

65 to 150 PSI

(4.5 Bar. TO 10.3 Bar.)

RECOMMEND INPUT WIRE AND FUSE SIZES

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30oC or Less

Output

AC Input

 

Fuse

Type 75oC

Input Cord

 

Voltage

Plug

(Super Lag)

Copper Wire in Conduit

 

at

Size

Circuit Breaker

AWG (IEC) Sizes

 

50/60

 

(Delay Type)

 

 

 

Hertz

 

 

2 Input Supply Wires

1 Ground Wire

 

 

 

 

 

 

25 A

230V-1Ø

 

20 AMPS

#14 (2.5 mm2)

#14 (2.5 mm2)

6-20P or 6-30P or 6-50P

 

 

 

 

 

 

15 A

115V-1Ø

5-15P* or 5-20P* or 5-30P or 5-50P

15 AMPS

#12 (4 mm2)

#12 (4 mm2)

20 A

115V-1Ø

5-20P* or 5-30P or 5-50P

20 AMPS

#12 (4 mm2)

#12 (4 mm2)

25 A

115V-1Ø

5-30P or 5-50P

30 AMPS

#12 (4 mm2)

#12 (4 mm2)

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

10.2in. 260 mm

Width

6.3in.

160 mm

Depth

16.1in. 410 mm

Weight

Including

Torch Cable

35lbs. 15.9 kg.

* Included with machine

PRO-CUT 25

Image 8
Contents PRO-CUT TM Safety Electric Shock can killPlasma ARC can injure Page Précautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately Table of Contents Installation Technical Specifications PRO-CUT 25 K1756-1Safety Precautions Electric Shock can Kill Select Proper LocationHigh Frequency Interference Protection Input Electrical ConnectionsGAS Input Connections Output Connections TorchSafety Precautions Preheat Temperature for Plasma CuttingOperation DescriptionUser Responsibility Operational Features and ControlsDesign Features Advantages Cutting Capability Consumable LifeControls and Settings LimitationsPilot ARC Discussion Electric Shock can KillProcedure Recommendations General In All CasesAccessories General Options AccessoriesPeriodic Maintenance MaintenanceRoutine Maintenance Troubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Problems Or dross Symptom Check PRO-CUT 25 Wiring Diagram SW1Precaucion Warnung
Related manuals
Manual 29 pages 20.43 Kb