TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS
RECOMMENDED
COURSE OF ACTION
The | |
there is no response when the trig- | the |
ger is pulled and only the POWER | then: |
LED is lit. | a. Reconnect Board may be |
| faulty. |
| b. The main gas solenoid assem- |
| bly may be faulty. Check or |
| replace. |
| c. Possible faulty Control board. |
2.Remove the handles (or barrel) of the torch and examine all the con- nections. Pay attention to location of electrode lead mounting at back of torch head, broken trigger and solenoid leads.
3.Check for proper trigger switch
operation. Remove the torch cable
assembly from the Pro Cut and If all recommended possible areas of test for continuity between 1 and 2 misadjustment have been checked at the Green 4 Pin Connector and the problem persists, Contact when the trigger switch is your local Lincoln Authorized depressed and no continuity when Field Service Facility.
the switch is not depressed. Replace the trigger switch or torch cable if defective.
4.Possible faulty Control board.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.