Lincoln Electric IM632-B manual Function Problems

Page 16

E-2

 

TROUBLESHOOTING

 

E-2

 

 

 

 

 

 

Observe all Safety Guidelines detailed througout this manual

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE CAUSE

RECOMMENDED

 

 

(SYMPTOMS)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

1. Drive rolls turn, but wire will not

A. Gun cable kinked and/or twisted.

feed or wire feeding is rough.

 

 

B. Wire jammed in gun and cable.

C.Incorrect drive rolls and guide tubes.

D.Gun cable liner dirty.

E. Worn drive rolls.

F. Electrode rusty and/or dirty.

G.Worn or improper size cable liner.

H.Partially flashed, melted, or improper size contact tip.

I. Incorrect diffuser

2. Variable or “hunting” arc.

A. Contact tip worn or incorrect size.

 

B. Worn or undersize ground cables

 

or poor ground connections.

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

C.Loose electrode connections.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MAGNUM® 450WC & 650WC

Image 16
Contents Magnum Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Installation Description Product NumberOperation Electrodes and EquipmentExpendable Replacement Parts Part Number English Metric DescriptionMaintenance Gun Tube Replaceable PartsREMOVAL, Installation and Trimming Instructions for Liners Liner Wire Size Stencil on Liner Bushing Color GUNFitting a Soft Liner for Feeding Aluminum Electrode Troubleshooting HOW to USE Troubleshooting GuideFunction Problems Troubleshooting Magnum 450WC & 650WC Ground Fuera del área de trabajo CuerpoInflammable Votre corps PerschutzKeep your head out of fumes Guards offUse ventilation or exhaust to Desconectar el cable de ali No operar con panel abierto o