Lincoln Electric IM491-B manual Plasma ARC can injure

Page 3

4.g. Sparks and spatter are thrown from the plasma arc. Wear safety glasses, ear protection and oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when cutting or gouging out of position or in confined places. Always wear safety glasses with side shields when in a cutting or gouging area.

4.h. Connect the work cable to the work as close to the cutting or gouging area as practical. Work cables connected to the build- ing framework or other locations away from the cutting or gouging area increase the possibility of the current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.

PLASMA ARC can injure.

7.a. Keep your body away from nozzle and plasma arc.

7.b. Operate the pilot arc with caution. The pilot arc is capable of burning the operator, others or even piercing safety clothing.

CYLINDER may explode if damaged.

5.a. Use only compressed gas cylinders contain-

ing the correct gas for the process used and properly operating regulators designed for the gas and pressure used. All hoses,

fittings, etc. should be suitable for the application and main- tained in good condition.

5.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

5.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from plasma cutting or gouging, arc weld- ing operations and any other source of heat, sparks,

or flame.

5.d. Never allow any part of the electrode, torch or any other electrically “hot” parts to touch a cylinder.

5.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

5.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

5.g. Read and follow the instructions on compressed gas cylin- ders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,”available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

6.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

6.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s rec- ommendations.

6.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

– 3 –

ELECTRIC AND MAGNETIC FIELDS may be dangerous

8.a. Electric current flowing through any con- ductor causes localized Electric and Magnetic Fields (EMF). Cutting or gouging current creates EMF fields around torch cables and cutting machines.

8.b. EMF fields may interfere with some pacemakers, so opera- tors having a pacemaker should consult their physician before cutting or gouging.

8.c. Exposure to EMF fields during cutting or gouging may have other health effects which are now not known.

8d. All operators should use the following procedures in order to minimize exposure to EMF fields from the cutting or gouging circuit:

8.d.1. Route the torch and work cables together - Secure them with tape when possible.

8.d.2. Never coil the torch cable around your body.

8.d.3. Do not place your body between the torch and work cables. If the torch cable is on your right side, the work cable should also be on your right side.

8.d.4. Connect the work cable to the workpiece as close as possible to the area being cut or gouged.

8.d.5. Do not work next to cutting power source.

Apr. ‘93

Image 3
Contents PRO-CUT Electric Shock can kill Plasma ARC can injure Sûreté Pour Soudage a L’Arc Précautions DE SûretéTable of Contents Please Examine Carton and Equipment For Damage Immediately Specifications Preheat Temperature for Plasma Cutting Product DescriptionUser Responsibility High Frequency Interference Protection LocationElectric Shock can kill Electrical Input ConnectionOutput Connections Torch ConnectionSequence of events Material thickness below .75 19mm Procedure RecommendationsPilot Arc Discussion GeneralExpanded Metal Material Thickness above .75 19mmGouging All Cases Suggestions for Extra Utility from the PRO-CUT SystemTighten the Electrode Electrical Shock can Kill Routine MaintenanceTroubleshooting Guide Visual InspectionSymptom Check Symptom Check Symptom Check Check to see that the torch is hooked to Status Lights Condition Suggestions PRO-CUT 125 Status Lights Operating ModesSafety Procedure for Replacing PC Boards Electric Shock can Kill Page PCT 125 AMP Plasma Torch PCT 125 AMP Plasma Torch General Assembly PRO-CUT 125 Three Phase Parts List P-207-C.1 L8348 28-93 Case Back AssemblySolenoid Assembly S18669-1 28-93B Regulator and Filter AssemblyInput BOX Assembly R K HI Freq Board AssemblyCase Front Assembly Single Voltage Plasma Torch Connection Diagram For Lincoln Electric Torches Wiring Diagram PRO-CUT Basic Course How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Warnung