INPUT SUPPLY CONNECTION DIAGRAM

FOR SINGLE VOLTAGE MACHINE.

NOTE: MACHINES ARE SHIPPED FROM FACTORY CONNECTED

GND.

 

 

 

LINK

 

 

 

 

 

 

 

 

FOR 575 VOLTS

 

 

 

 

 

 

575 V.,60HZ.

 

LINK POSITIONS

 

 

U

U

T3

9

 

 

 

 

 

 

 

 

 

 

 

 

 

11

6

 

 

V

V

5

 

 

 

 

 

 

 

 

 

8

10

12

 

 

 

 

 

 

 

W

W

 

T1

 

 

 

 

4

1.

CONNECT U, V, & W INPUT SUPPLY LINES TO STUDS

 

T2

 

 

 

MARKED U, V, & W ON RECONNECT PANEL.

 

 

 

7

 

 

 

 

 

2.

CONNECT TERMINAL MARKED

TO GROUND PER

 

 

 

 

NATIONAL ELECTRICAL CODE.

 

 

 

 

3.REMOVE HEX NUTS AND POSITION LINKS AS SHOWN. REPLACE AND TIGHTEN ALL HEX NUTS.

THE LINCOLN ELECTRIC CO., CLEVELAND, OHIO U.S.A.

1-14-94B

 

 

 

 

 

M17491

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 1- SINGLE VOLTAGE

INPUT SUPPLY CONNECTION DIAGRAM FOR TRIPLE VOLTAGE MACHINE.

NOTE: MACHINES ARE SHIPPED FROM FACTORY CONNECTED

FOR 440 (OR 460) VOLTS

GND.

440V.,50HZ.

460V.,60HZ.

{

U

V

W

 

LINK POSITIONS

LINK

U

T3

9

 

 

 

 

 

11

6

 

V

5

 

 

 

 

 

 

 

12

 

 

8

 

 

 

10

 

T1

W

4

 

 

 

 

 

T2

 

 

 

 

 

7

 

380 V.,50HZ.

 

LINK POSITIONS

LINK

GND.

{

U

U

9

 

 

 

 

 

T3

 

 

 

 

 

11

 

 

 

V

V

6

 

 

 

5

12

 

 

 

 

 

 

 

 

8

 

T1

 

 

W

10

 

 

 

W

 

 

 

 

4

 

 

 

 

T2

 

7

1. CONNECT U, V, & W INPUT SUPPLY LINES TO STUDS

 

220 V.,50HZ.

 

LINK POSITIONS

LINK

 

230 V.,60HZ.

 

MARKED U, V, & W ON RECONNECT PANEL.

 

 

 

 

 

 

 

 

GND.

{

 

 

T3

 

 

 

 

 

U

U

 

 

2. CONNECT TERMINAL MARKED

TO GROUND PER

 

 

 

 

9

 

 

 

 

 

 

 

 

NATIONAL ELECTRICAL CODE.

 

 

 

 

 

11

6

 

 

 

 

V

V

 

 

 

 

 

 

 

 

5

12

 

 

 

 

 

 

 

 

3. REMOVE HEX NUTS AND POSITION LINKS AS SHOWN.

 

 

W

8

10

T1

 

REPLACE AND TIGHTEN ALL HEX NUTS.

 

 

 

W

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

T2

7

 

THE LINCOLN ELECTRIC CO., CLEVELAND, OHIO U.S.A.

5 - 2 8 - 9 3

 

 

 

 

M16437

 

 

 

 

 

 

 

FIGURE 1- DUAL & TRIPLE VOLTAGE

– 34 –

Image 34
Contents PRO-CUT Electric Shock can kill Plasma ARC can injure Précautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Please Examine Carton and Equipment For Damage Immediately Specifications Product Description Preheat Temperature for Plasma CuttingUser Responsibility Location High Frequency Interference ProtectionElectrical Input Connection Electric Shock can killTorch Connection Output ConnectionsSequence of events General Procedure RecommendationsPilot Arc Discussion Material thickness below .75 19mmMaterial Thickness above .75 19mm Expanded MetalGouging Suggestions for Extra Utility from the PRO-CUT System All CasesTighten the Electrode Visual Inspection Routine MaintenanceTroubleshooting Guide Electrical Shock can KillSymptom Check Symptom Check Symptom Check Check to see that the torch is hooked to PRO-CUT 125 Status Lights Operating Modes Status Lights Condition SuggestionsSafety Procedure for Replacing PC Boards Electric Shock can Kill Page PCT 125 AMP Plasma Torch PCT 125 AMP Plasma Torch General Assembly PRO-CUT 125 Three Phase Parts List P-207-C.1 Case Back Assembly L8348 28-93Solenoid Assembly Regulator and Filter Assembly S18669-1 28-93BInput BOX Assembly HI Freq Board Assembly R KCase Front Assembly Single Voltage Plasma Torch Connection Diagram For Lincoln Electric Torches Wiring Diagram PRO-CUT Need Welding Training? How To Read Shop DrawingsNew Lessons in Arc Welding Basic CoursePrecaucion Warnung