Aging Method
1.Change the [COMMANDÊMODE] switch (S901) on set to
[CD1].
2.Turn ON the power of the unit. Open the front cover.
3.Press the [AGINGÊSTART] button of the remote commander for aging mode
4.When the disc set mode is set, the á and P LEDs blink.
5.Rotate the JOG dial. The slits (No. 40, 80, 120, 160, 200) for setting the discs will come forward. Insert the discs into these slits. Do not set the discs in other slits.
6.Set whether the
7.Press the á button.
8.The á LED blinks, the aging mode is set, and aging is started.
9.The aging cycle lasts 3 minutes. If errors occur during aging, the error number will be displayed on the Fluorescent indica- tor tube. (Refer to the following table for the details of the errors.)
10.Aging will be repeated as long as no errors occur.
11.After each aging cycle, the number displayed on the Fluores- cent indicator tube will increase.
12.To end aging, press the I/u button
Error Display
1 2 0 | E r r 0 1 |
| |
⎛ ⎜ ⎝ | ⎛ ⎜ ⎝ |
| |
Disc number | Error code |
| |
Error code |
|
|
|
|
|
|
|
Code number |
| Name | Contents |
|
|
|
|
Err 01 |
| DISC sensor check 1 | No disc in the specified slit |
|
|
|
|
Err 02 |
| DISC sensor check 2 | Disc in other slits |
|
|
|
|
Err 03 |
| Table operation check 1 | Table motor current over |
|
|
|
|
Err 04 |
| Table operation check 2 | No table sensor input |
Err 05 |
| Loading operation check 1 | Load in timeover |
|
|
|
|
Err 06 |
| Loading operation check 2 | Load out timeover |
|
|
|
|
Err *1 |
| BU related check 1 | Access timeover |
|
|
|
|
Err *2 |
| BU related check 2 | High speed search NG |
|
|
|
|
Err *3 |
| BU related check 3 | Q data read error |
Err *4 |
| BU related check 4 | BU operation (from focus search to until signal can be read) timeover |
|
|
|
|
Err *5 |
| BU related check 5 | GFS monitor error |
|
|
|
|
Err *6 |
| BU related check 6 | Focus cannot be imposed by focus search |
|
|
|
|
Err *7 |
| BU related check 7 | Auto focus bias adjustment cannot be performed |
|
|
|
|
The * numbers mean the following according to the state of the unit during aging 2 : From checking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback