Sony Ericsson CDP-CX220 service manual E r r, Aging Method, Error Display, Error code

Models: CDP-CX220

1 56
Download 56 pages 50.74 Kb
Page 12
Image 12
Aging Method

Aging Method

1.Change the [COMMANDÊMODE] switch (S901) on set to

[CD1].

2.Turn ON the power of the unit. Open the front cover.

3.Press the [AGINGÊSTART] button of the remote commander for aging mode (J-2501-123-A).

4.When the disc set mode is set, the á and P LEDs blink.

5.Rotate the JOG dial. The slits (No. 40, 80, 120, 160, 200) for setting the discs will come forward. Insert the discs into these slits. Do not set the discs in other slits.

6.Set whether the self-protection function during errors is equipped with the unit. Press the [REPEAT] button. If “RE- PEAT” is displayed on the Fluorescent indicator tube, it means the function is provided. If “REPEAT” is not displayed, it means the function is not provided.

7.Press the á button.

8.The á LED blinks, the aging mode is set, and aging is started.

9.The aging cycle lasts 3 minutes. If errors occur during aging, the error number will be displayed on the Fluorescent indica- tor tube. (Refer to the following table for the details of the errors.)

10.Aging will be repeated as long as no errors occur.

11.After each aging cycle, the number displayed on the Fluores- cent indicator tube will increase.

12.To end aging, press the I/u button

Error Display

1 2 0

E r r 0 1

 

⎛ ⎜ ⎝

⎛ ⎜ ⎝

 

Disc number

Error code

 

Error code

 

 

 

 

 

 

 

Code number

 

Name

Contents

 

 

 

 

Err 01

 

DISC sensor check 1

No disc in the specified slit

 

 

 

 

Err 02

 

DISC sensor check 2

Disc in other slits

 

 

 

 

Err 03

 

Table operation check 1

Table motor current over

 

 

 

 

Err 04

 

Table operation check 2

No table sensor input

Err 05

 

Loading operation check 1

Load in timeover

 

 

 

 

Err 06

 

Loading operation check 2

Load out timeover

 

 

 

 

Err *1

 

BU related check 1

Access timeover

 

 

 

 

Err *2

 

BU related check 2

High speed search NG

 

 

 

 

Err *3

 

BU related check 3

Q data read error

Err *4

 

BU related check 4

BU operation (from focus search to until signal can be read) timeover

 

 

 

 

Err *5

 

BU related check 5

GFS monitor error

 

 

 

 

Err *6

 

BU related check 6

Focus cannot be imposed by focus search

 

 

 

 

Err *7

 

BU related check 7

Auto focus bias adjustment cannot be performed

 

 

 

 

The * numbers mean the following according to the state of the unit during aging 2 : From checking to end of TOC read

3 : From end of TOC read to end of last track playback

4 : From end of last track playback to end of first track playback

– 12 –

Page 12
Image 12
Sony Ericsson CDP-CX220 service manual E r r, Aging Method, Error Display, Error code