Lincoln Electric 11079 manual STARTING/SHUTDOWN Instructions, BREAK-IN Period, Starting the Engine

Page 21

B-5

OPERATION

B-5

 

 

 

STARTING/SHUTDOWN INSTRUCTIONS

STARTING THE ENGINE

WARNING

• Do not touch electrically live parts of electrode with skin or wet clothing.

Keep flammable material away.

Insulate yourself from work and

ground. Wear eye, ear, and body protection.

• Keep your head out of the fumes.

• Use ventilation or exhaust to remove fumes from breathing zone.

Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner’s Manual before starting for the first time.

Remove all loads connected to the AC power recepta- cles. Use the choke control as follows:

KOHLER ENGINE - Always pull the choke control out when starting the engine; cold, warm or hot.

Turn the engine switch to the start position and crank the engine until it starts. Release the switch as soon as the engine starts, slowly return the choke control to the full inposition (choke open),

and turn the switch to the Auto Idle( / ) position. Do not turn the switch to the startposition while the engine is running because this will cause damage to the ring gear and/or starter motor

After running at high engine speed for 10-14 seconds, the engine will go to low idle. Allow the engine to warm up by letting it run at low idle for a few minutes.

STOPPING THE ENGINE

Remove all welding and auxiliary power loads and allow engine to run at low idle speed for a few minutes to cool the engine.

Stop the engine by placing the Engine switch in the

OFF position.

A fuel shut off valve is not required on the RANGER

3 PHASE because the fuel tank is mounted below the engine.

BREAK-IN PERIOD

It is normal for any engine to use a greater amount of oil until the break-in is accomplished. Check the oil level twice a day during the break-in period (approxi- mately 50 running hours).

IMPORTANT: IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE UNIT SHOULD BE SUBJECTED TO MODERATE LOADS, WITHIN THE RATING OF THE MACHINE. AVOID LONG IDLE RUNNING PERIODS. REMOVE LOADS AND ALLOW ENGINE TO COOL BEFORE SHUTDOWN.

The engine manufacturers recommendation for the running time until the first oil change is as follows:

KOHLER

CH20SI

5 HRS

The oil filter is to be changed at the second oil change. Refer to the Engine Owners Manual for more information.

RANGER 3 PHASE

Image 21
Contents Ranger Phase California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Ranger 3 Phase K2337-1 InstallationHeight Width Depth Weight Ranger 3 PhaseMachine Grounding Safety PrecautionsSpark Arrester TowingPRE-OPERATION Service Angle of Operation Connection of Lincoln Electric Wire FeedersLifting High Altitude OperationAuxiliary Power Additional Safety PrecautionsInstructions Welder OperationGround Wire Volt 3 Phase Receptacle with GroundRanger 3 Phase Extension Cord Length Recommendations Gfci Duplex ReceptaclesType Common Electrical Devices Possible Concerns Electrical Device USE with the Ranger 3 PhaseAuxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections Connection of Ranger 3 Phase to Premises Wiring Operation Engine SwitchGeneral Description Welder Controls Function and OperationRanger 3 Phase Approximate Fuel Consumption Polarity SwitchWelding Process Wire Feed Welding Processes Constant VoltageStick Constant Current Welding TIG Constant Current WeldingStick Auto BREAK-IN Period STARTING/SHUTDOWN InstructionsStarting the Engine Stopping the EngineK1745-1 GAS Cylinder Holder AccessoriesRecommended Equipment Wire FeedStick TIGSafety Precautions MaintenanceRoutine Maintenance Engine OIL Refill Capacities Engine OIL ChangeAIR Cleaner and Other Maintenance Gfci Receptacle Testing and RESET- Ting ProcedureOIL Filter Change Engine Adjustments HOW to USE Troubleshooting Guide TroubleshootingYour local Lincoln Authorized Field Service Facility Troubleshooting Ranger 3 Phase DiagramsEngine Welder M20397 Ranger 3 Phase Precaucion Warnung