Lincoln Electric IM831, 11079 manual Stick Auto

Page 20

 

B-4

 

 

OPERATION

B-4

 

 

 

 

 

 

 

 

 

 

 

 

SUMMARY OF WELDING PROCESSES

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

ELECTRODE

 

 

 

 

 

CABLE

IDLE

WHEN NOT

TO START

 

 

 

PROCESS

USED

MODE

WELDING

WELDING

 

 

 

 

 

 

 

 

 

STICK

No

AUTO

Hot

Touch electrode to work.

 

 

 

 

 

 

 

Welding starts immediately

 

 

 

 

 

 

 

and engine goes to high

 

 

 

 

 

 

 

idle.

 

 

 

 

 

 

 

 

 

WIRE FEED, LN-25 WITH

No

AUTO

Cold

Press gun trigger, LN-25

 

 

INTERNAL CONTACTOR

 

 

 

contactor closes. Welding

 

 

 

 

 

 

 

starts immediately and

 

 

 

 

 

 

 

engine goes to high idle.

 

 

 

 

 

 

 

NOTE: Output Control

 

 

 

 

 

 

 

must be set above “3”

 

 

 

 

 

 

 

 

 

TIG, TIG MODULE WITH

Yes

High

Cold

Press Arc Start Switch

 

 

WITH CONTACTOR KIT

 

 

 

contactor closes,

 

 

CONTROL CABLE, & ARC

 

 

 

welding starts immediately.

 

 

START SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

WIRE FEED, LN-15

No

Auto

Cold

Press gun trigger.

 

 

ACROSS the ARC

 

 

 

LN-15 contactor closes,

 

 

(has internal contactor)

 

 

 

Welding starts immediately

 

 

 

 

 

 

 

Note: Output Control must

 

 

 

 

 

 

 

be set above “3”.

 

 

 

 

 

 

 

 

 

RANGER 3 PHASE

Image 20
Contents Ranger Phase Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Ranger 3 Phase K2337-1Height Width Depth Weight Ranger 3 PhaseSafety Precautions Machine GroundingSpark Arrester TowingPRE-OPERATION Service Connection of Lincoln Electric Wire Feeders Angle of OperationLifting High Altitude OperationAdditional Safety Precautions Auxiliary PowerInstructions Welder OperationVolt 3 Phase Receptacle with Ground Ground WireRanger 3 Phase Extension Cord Length Recommendations Gfci Duplex ReceptaclesElectrical Device USE with the Ranger 3 Phase Type Common Electrical Devices Possible ConcernsStandby Power Connections Auxiliary Power While WeldingSimultaneous Welding and Power Connection of Ranger 3 Phase to Premises Wiring Engine Switch OperationGeneral Description Welder Controls Function and OperationPolarity Switch Ranger 3 Phase Approximate Fuel ConsumptionWire Feed Welding Processes Constant Voltage Welding ProcessStick Constant Current Welding TIG Constant Current WeldingStick Auto STARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineAccessories K1745-1 GAS Cylinder HolderWire Feed Recommended EquipmentStick TIGMaintenance Safety PrecautionsRoutine Maintenance Engine OIL Refill Capacities Engine OIL ChangeOIL Filter Change AIR Cleaner and Other MaintenanceGfci Receptacle Testing and RESET- Ting Procedure Engine Adjustments Troubleshooting HOW to USE Troubleshooting GuideYour local Lincoln Authorized Field Service Facility Troubleshooting Diagrams Ranger 3 PhaseEngine Welder M20397 Ranger 3 Phase Precaucion Warnung