Lincoln Electric V200-T manual Installation, Technical Specifications V200T TIG

Page 8

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - V200T TIG

INPUT - SINGLE PHASE ONLY

Standard

Voltage (1)

230/460/1/50/60

Duty Cycle (2)

20% Duty Cycle

60% Duty Cycle

100% Duty Cycle

Output Current

Range

1 - 200 A

Input Current at

Rated Output

45/23 A @ 200 A, 33/16 A @ 150 A,

25/13 A @ 120 A

RATED OUTPUT

Amps

200

150

120

OUTPUT

Maximum Open

Circuit Voltage

80 V

Code

Number

10463

Volts at Rated Amperes

28

26

25

Type of Output

DC

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For DC TIG Welding at 200A/20% Duty Cycle

 

 

 

 

 

 

Based on the 1996 U.S. National Electrical Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

Input

 

 

 

Fuse

 

Input

 

 

Type 75°C

 

Copper Ground

 

Voltage /

 

 

(Super Lag)

 

Ampere

 

 

Copper Wire in

 

Wire in Conduit

 

phase/

 

 

or Breaker

 

Rating on

 

 

Conduit AWG

 

AWG (IEC)

 

Frequency

 

 

 

Size

 

Nameplate

 

 

(IEC) Sizes

 

Sizes

 

230/1/50/60

 

 

50

 

45

 

 

10 (5.2 mm2)

 

10 (5.2 mm2)

 

460/1/50/60

 

 

30

 

23

 

 

12 (4 mm2)

 

12 (4 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Power Source

Height

10.04in. 255 mm

Width

7.48in. 190 mm

Depth

17.32in. 440 mm

Weight

Approx. 35 lbs. 16 kgs.

OPERATING TEMPERATURE

STORAGE TEMPERATURE

-20°C to +40°C

-25°C to +55°C

(1)Input voltage must be within ±10% of rated value.

(2)Duty Cycle is based on a 10 min. period.

INVERTEC V200-T

Image 8
Contents Safety Depends on You InvertecSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications V200T TIGSelect Suitable Location Electric Shock can killInput Connections Input Fuse and Supply WireOutput Connections Output Connection for Stick Welding Output and GAS Connection for TIG WeldingCylinder could explode if damaged General Description Safety InstructionsOperation Controls and Settings Figure B.1 Case Front ControlsOperation Welding in TIG Mode Remote Control OperationOperating Steps Sept97Welding in Stick Mode Set the Welding Process Switch to StickRecommended Electrode Amperage Ranges Invertec V200-T Smaw ProcessPulser Function Explanation of 2 Step and 4 Step ModesStep Cable Plugs AccessoriesOptional Accessories Maintenance Safety PrecautionsInput Filter Capacitor Discharge Procedure Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Diagrams Invertec V200-T PartsInvertec V-200-T 308-A.1308-C 11-4-98308-C.1 Items Not ShownInvertec V-200-T How To Read Shop Drawings $700.00Precaucion Warnung