Lincoln Electric V205-T AC/DC TIG manual DC TIG Welding Quick Start UP

Page 24

B-11

OPERATION

B-11

 

 

 

DC TIG WELDING QUICK START UP

WARNING

ELECTRIC SHOCK can kill.

Have an electrician install and service this equipment.

Turn the input power off at the fuse box, dis- connect or unplug supply lines and allow machine to sit for five minutes minimum to allow the power capacitors to discharge before working inside this equipment.

Do not touch electrically hot parts.

------------------------------------------------------------------------

Connect up the shielding gas – typically argon – using an appropriate regulator. Connect foot amptrol, torch and work lead to power source.

With the Work cable connected to a properly ground- ed work piece, turn the power source on.

To change to DC TIG Welding:

Press Mode button to select "DC TIG."

Press Trigger Mode button and set to 2-step.

Press Local / Remote Mode button and set for Remote.

Pulsing parameters selected by Parameter button, and changed using Output Control.

Set the maximum output current desired using the

Output Control.

Initiate the arc by closing the Foot Amptrol’s arc start switch. The Amptrol will control the output current from 10 amps to current level set by output control.

To change the Post Flow time, repeatedly push the Parameter button until the Post Flow indicator light is on. Adjust the Output control to the desired Post Flow time as indicated on digital display.

To change from High Frequency to Lift Start, turn power source off. Press and hold the Parameter but- ton while the power source is turned on. A “0” in the center of the digital display indicates the Set Up Menu is now active. Rotate the Output Control until # 8 is displayed. Press the Parameter button again and rotate the Output Control until “1” is displayed. Press the Parameter button to accept this setting. Rotate the Output Control until “0” is displayed. Press the para- meter button to exit the Set Up Menu.

V205-T AC/DC TIG

Image 24
Contents Invertec V205-T AC/DC TIG October Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately Table of Contents Installation Operating Temperature RangeStorage Temperature Range V205-T AC/DC TIGSelect Suitable Location StackingTilting Environmental AreaReconnect Procedure Input ConnectionsAttachment Plug Installation 230V Input115V Input Engine Driven GeneratorOutput and GAS Connection for TIG Welding Figure A.1 Output Connection for Stick Welding Figure A.2Work Cable Connection Remote Control Connection Shielding GAS ConnectionSafety Instructions OperationGeneral Description Welding CapabilityRear Control Panel Figure B.1 Figure B.1Controls and Settings Figure B.2Step Diagram Tig Trigger SequencesTIG DC TIG AC SET UP Menu Indicator Parameter DefaultOutput Limitations Welding PolarityFigure B.5 Steel TIG Welding Copper TIG WeldingTips for AC TIG Welding Filler MaterialAC TIG Welding Quick Start UP Protective GASDC TIG Welding Quick Start UP Accessories Optional AccessoriesCompatible Equipment Cable PlugsMaintenance Safety PrecautionsInput Filter Capacitor Discharge Procedure Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Play Wiring Diagrams Wiring Diagram K1855-1V205-T AC/DC TIG V205-T AC/DC TIG Precaucion Warnung