Lincoln Electric V205-T AC/DC TIG manual Installation, Operating Temperature Range

Page 8

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - V205-T AC/DC TIG K1855-1 (Code Number 10860)

INPUT - SINGLE PHASE ONLY

Input Voltages / 50 /60 Hz.

115

230

Max. Input Current

34A at Rated Output

30A at Rated Output

 

RATED OUTPUT

 

Duty Cycle

Output Amps

Volts at Rated Amperes

Input Amps

(115V) 35%

(Stick) 110

24.4V

34A

60%

90

23.6V

28A

100%

70

22.8V

20A

 

 

 

 

(115V) 40%

(TIG) 150

16V

34A

60%

120

14.8V

25A

100%

100

14V

20A

 

 

 

 

(230V) 35%

(Stick) 180

27.2V

30A

60%

150

26V

23A

100%

130

25.2V

19A

 

 

 

 

(230V) 40%

(TIG) 200

18V

30A

60%

170

16V

18A

100%

140

15.6V

15A

 

 

 

 

 

 

 

 

Output Current

Range

6-200 Amps

OUTPUT

Maximum Open

Circuit Voltage

54 Volts Max.

Type of Output

AC/DC

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

 

INPUT

TYPE S, SO ST, STO, OR EXTRA

TIME-DELAY CIRCUIT BREAKER

 

VOLTAGE /

HARD USAGE INPUT CORD AWG

OR FUSE SIZE (AMPS)

 

FREQUENCY

 

 

 

 

 

(HZ)

 

 

 

 

 

 

 

 

 

 

 

115/50/60

#12

 

30A

 

230/50/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

Height

 

Width

 

Depth

 

Weight

15 in.

 

8.5 in.

 

19 in.

 

Approx. 38 lbs.

381 mm

 

216 mm

 

483 mm

 

17 kgs.

 

 

 

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-50°C to +85°C

V205-T AC/DC TIG

Image 8
Contents Invertec V205-T AC/DC TIG October Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately Table of Contents Installation Operating Temperature RangeStorage Temperature Range V205-T AC/DC TIGSelect Suitable Location StackingTilting Environmental AreaReconnect Procedure Input ConnectionsAttachment Plug Installation 230V Input115V Input Engine Driven GeneratorWork Cable Connection Output and GAS Connection for TIG Welding Figure A.1Output Connection for Stick Welding Figure A.2 Remote Control Connection Shielding GAS ConnectionSafety Instructions OperationGeneral Description Welding CapabilityRear Control Panel Figure B.1 Figure B.1Controls and Settings Figure B.2Step Diagram Tig Trigger SequencesTIG DC TIG AC SET UP Menu Indicator Parameter DefaultOutput Limitations Welding PolarityFigure B.5 Steel TIG Welding Copper TIG WeldingTips for AC TIG Welding Filler MaterialAC TIG Welding Quick Start UP Protective GASDC TIG Welding Quick Start UP Accessories Optional AccessoriesCompatible Equipment Cable PlugsMaintenance Safety PrecautionsInput Filter Capacitor Discharge Procedure Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Play Wiring Diagrams Wiring Diagram K1855-1V205-T AC/DC TIG V205-T AC/DC TIG Precaucion Warnung