Lincoln Electric 215 manual Input POWER, Grounding, Connection Diagrams Safety Precautions

Page 10

A-2

INSTALLATION

A-2

Read entire installation section before starting

INPUT POWER, GROUNDING AND

installation.

 

CONNECTION DIAGRAMS

 

SAFETY PRECAUTIONS

WARNING

 

 

WARNING

ELECTRIC SHOCK can kill.

 

 

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such as

 

• Only qualified personnel should

output terminals or internal wiring.

 

 

perform this installation.

• All input power must be electrically dis-

 

• Only personnel that have read

connected before proceeding.

 

 

and understood the POWER MIG

 

 

 

215 Operating Manual should

 

 

 

install and operate this equip-

1. Before starting the installation, check with the local

 

ment.

 

• Machine must be grounded per

power company if there is any question about

 

any national, local or other applic-

whether your power supply is adequate for the volt-

 

able electrical codes.

age, amperes, phase, and frequency specified on

 

• The POWER MIG power switch is

the welder nameplate. Also be sure the planned

 

to be in the OFF position when

installation will meet the U.S. National Electrical

 

installing work cable and gun and

Code and local code requirements. This welder

 

when connecting other equip-

may be operated from a single phase line or from

 

ment.

one phase of a two or three phase line.

 

UNCRATING THE POWER MIG 215

2. Models that have multiple input voltages specified

on the nameplate (e.g. 208/230) are shipped con-

Cut banding and lift off cardboard carton. Cut banding

nected for the highest voltage. If the welder is to be

holding the machine to the skid. Remove foam and

operated on lower voltage, it must be reconnected

corrugated packing material. Untape accessories from

according to the instructions in Figure A.1 for dual

Gas Bottle Platform. Unscrew the two wood screws

voltage machines.

 

(at the Gas Bottle Platform) holding the machine to

WARNING

 

the skid. Roll the machine off the skid assembly.

 

LOCATION

 

Make certain that the input power is electrically

Locate the welder in a dry location where there is free

disconnected before removing the screw on the

circulation of clean air into the louvers in the back and

reconnect panel access cover.

 

out the front. A location that minimizes the amount of

------------------------------------------------------------------------

smoke and dirt drawn into the rear louvers reduces

 

 

the chance of dirt accumulation that can block air pas-

 

 

sages and cause overheating.

 

 

POWER MIG 215

Image 10
Contents Power MIG Electric Magnetic Fields SafetyFor Engine Chemicals known to the State of California to causeFumes and Gases AUGIii For ElectricallyJan LES Machines À Souder À Précautions DE SûretéPrécautions DE Sûreté Pour Transformateur ET ÀThank You As much pride as we have in bringing this product to youMaster Table of Contents for ALL Sections Master Table of Contents for ALL Sections Installation Technical Specifications Power MIGConnection Diagrams Safety Precautions Input POWER, GroundingUncrating the Power MIG Figure A.2 Receptacle Diagram Figure A.1 Dual Voltage Machine Input ConnectionsGUN and Cable Installation Shielding GAS1OPERATIONB-1 Wear eye, ear and body protec- tionOperation Wire Drive RollWire Size Conversion Parts Product Description LimitationsTo Start the Welder Drive and Idle Roll SetsSpools or Coils To Mount 10 to 44 Lb .5-20 kg Spools 12/300Feeding Wire Electrode Making a Weld Variations Avoiding Wire FeedingProblems ProtectionAccessories With the Spool GUN Adapter KIT and Spool GUN Installed Maintenance Ment Cause poor wire feedingLiner Removal and Replace This screw should only be gently tightenedGUN Handle Disassembly Troubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Not activated Gun assembly is faulty. Repair orContact your local Lincoln Feed but drive rolls are turning Position of groovesWire feed stops while welding Click when the gun trigger isWiring Diagrams Wiring Diagrams Dimension Print Power MIG Power MIG Ground Aspiración para gases