Lincoln Electric 215 manual Installation, Technical Specifications Power MIG

Page 9

 

A-1

 

 

 

 

INSTALLATION

 

 

 

A-1

 

TECHNICAL SPECIFICATIONS – POWER MIG 215

 

 

 

 

 

 

 

 

Standard Voltage/Phase/Frequency

 

 

Input Current @ 170 Amp Rated Output

 

Input Current @ 215 Amp Rated Output

 

 

 

 

 

 

 

 

 

208/230/1/50/60 Hz

 

 

 

(With 115V receptacle loaded to 15A)

 

(With 115V receptacle loaded to 15A)

 

 

 

 

 

 

 

 

39/35 Amps

 

 

45/41 Amps

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle

 

 

 

 

Amps

 

 

 

Volts at Rated Amperes

 

 

 

 

 

 

30%

 

 

 

215 Amps

 

 

 

22 Volts

 

 

40%

 

 

 

190 Amps

 

 

 

23 Volts

 

 

60%

 

 

 

170 Amps

 

 

 

24 Volts

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Welding Current Range

 

 

 

Maximum Open Circuit Voltage

 

Welding Voltage Range

 

 

 

 

 

 

 

 

30 – 250Amps

 

 

 

35 Volts

 

 

13.5-24 Volts

 

 

 

 

RECOMMENDED

 

INPUT WIRE AND FUSE

 

SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Ampere

 

75°C Copper Wire

 

75°C Copper Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Voltage/

 

Fuse or Breaker

 

 

in Conduit

 

in Conduit

 

 

 

 

 

Rating On

 

AWG (IEC) Sizes

 

AWG (IEC) Sizes

 

 

 

Frequency (Hz)

 

Size (Super Lag)

 

Nameplate

 

(For lengths

 

(For lengths

 

 

 

 

 

 

up to 100 ft.)

 

exceeding 100 ft.)

 

 

 

208/50/60

 

60

 

 

 

45A

 

10 (6 mm2)

 

8 (10 mm2)

 

 

 

230/50/60

 

60

 

 

 

41A

 

10 (6 mm2)

 

8 (10 mm2)

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

Use #10 AWG Grounding Wire

 

 

 

 

 

 

 

 

Wire Speed

WIRE SPEED RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 – 700 IPM (1.27 – 17.8 m/minute)

 

 

 

 

 

 

 

Height

Width

Depth

 

 

Weight

 

 

 

 

 

 

 

 

31.79 in

18.88 in

38.78 in

 

 

210 Ibs

 

 

 

808 mm

480 mm

985 mm

 

 

95 kg

 

 

 

 

 

TEMPERATURE RANGES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATING TEMPERATURE RANGE

 

 

STORAGE TEMPERATURE RANGE

 

 

 

 

 

 

 

 

 

-4°F to 104°F(-20°C to +40°C)

 

 

 

 

-40°F to 185°F(-40°C to +40°C)

 

 

POWER MIG 215

Image 9
Contents Power MIG For Engine SafetyElectric Magnetic Fields Chemicals known to the State of California to causeAUG Fumes and GasesFor Electrically IiiJan Précautions DE Sûreté Pour Précautions DE SûretéLES Machines À Souder À Transformateur ET ÀAs much pride as we have in bringing this product to you Thank YouMaster Table of Contents for ALL Sections Master Table of Contents for ALL Sections Technical Specifications Power MIG InstallationInput POWER, Grounding Connection Diagrams Safety PrecautionsUncrating the Power MIG Figure A.1 Dual Voltage Machine Input Connections Figure A.2 Receptacle DiagramShielding GAS GUN and Cable InstallationWear eye, ear and body protec- tion 1OPERATIONB-1Wire Size Conversion Parts Wire Drive RollOperation Product Description LimitationsSpools or Coils Drive and Idle Roll SetsTo Start the Welder To Mount 10 to 44 Lb .5-20 kg Spools 12/300Feeding Wire Electrode Making a Weld Problems Avoiding Wire FeedingVariations ProtectionAccessories With the Spool GUN Adapter KIT and Spool GUN Installed Maintenance Liner Removal and Replace Cause poor wire feedingMent This screw should only be gently tightenedGUN Handle Disassembly HOW to USE Troubleshooting Guide TroubleshootingNot activated Gun assembly is faulty. Repair or Authorized Field Service FacilityContact your local Lincoln Position of grooves Feed but drive rolls are turningClick when the gun trigger is Wire feed stops while weldingWiring Diagrams Wiring Diagrams Dimension Print Power MIG Power MIG Ground Aspiración para gases