Lincoln Electric IM901-A Safety Precautions, Location, High Frequency Protection, Weld CAbLE SIzE

Page 9

A-2

INSTALLATION

A-2

 

 

 

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK CAN KILL.

• Turn the input power OFF at the disconnect switch or fuse box before attempting to connect or disconnect input power lines, out- put cables or control cables.

Only qualified personnel should perform this installation.

Do not touch metal portions of the work clip when the welding power source is on.

Do not attach the work clip to the wire feeder.

Connect the work clip directly to the work, as close as possible to the welding arc.

Turn power off at the welding power source before disconnecting the work clip from the work.

Only use on power sources with open circuit voltages less than 110 VDC.

------------------------------------------------------------------------

LOCATION

For best wire feeding performance, place the LN- 25™ PRO on a stable and dry surface. Keep the wire feeder in a vertical position. Do not operate the wire feeder on an angled surface of more than 15 degrees.

Do not submerge the LN-25™ PRO.

The LN-25™ PRO is rated IP23 and is suitable for outdoor use.

The handle of the LN-25™ PRO is intended for moving the wire feeder about the work place only.

When suspending a wire feeder, insulate the hanging device from the wire feeder enclosure.

HIGH FREQUENCY PROTECTION

CAUTION

Locate the LN-25™ PRO away from radio controlled machinery. The normal operation of the LN-25™ PRO may adversely affect the operation of RF con- trolled equipment, which may result in bodily injury or damage to the equipment.

----------------------------------------------------------------------------

WELD CAbLE SIzE

Table A.1 located below are copper cable sizes rec- ommended for different currents and duty cycles. Lengths stipulated are the distance from the welder to work and back to the welder again. Cable sizes are increased for greater lengths primarily for the purpose of minimizing cable drop.

TAbLE A.1

RECOMMENDED CAbLE SIzES (RUbbER COVERED COPPER - RATED 167°F or 75°C)**

 

 

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES

AMPERES

PERCENT

 

 

 

 

 

 

DUTY

0 to 50Ft.

50 to 100Ft.

100 to 150 Ft.

150 to 200 Ft.

200 to 250 Ft.

 

CYCLE

(0 to15m)

(15 to 30m)

(30 to 46m)

(46 to 61m)

(61 to 76m)

 

 

 

 

 

 

 

 

 

 

 

 

 

200

60

2

2

2

1

1/0

200

100

2

2

2

1

1/0

225

20

4 or 5

3

2

1

1/0

225

40 & 30

3

3

2

1

1/0

250

30

3

3

2

1

1/0

250

40

2

2

1

1

1/0

250

60

1

1

1

1

1/0

250

100

1

1

1

1

1/0

300

60

1

1

1

1/0

2/0

325

100

2/0

2/0

2/0

2/0

3/0

350

60

1/0

1/0

2/0

2/0

3/0

400

60

2/0

2/0

2/0

3/0

4/0

400

100

3/0

3/0

3/0

3/0

4/0

500

60

2/0

2/0

3/0

3/0

4/0

 

 

 

 

 

 

 

**Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables larger than recommended, or cables rated higher than 167°F(75°C).

LN-25™ PRO ACROSS THE ARC MODEL

Image 9
Contents LN-25PRO Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTAbLE of Contents Installation Location Safety PrecautionsHigh Frequency Protection Weld CAbLE SIzEFunction Pin Wiring 3INSTALLATIONA-3CAbLE Connections Shielding GAS ConnectionChanging the GUN Receiver bUSHING Procedure to Install Drive Rolls and Wire GuidesLoading Spools of Wire Pressure ARM AdjustmentGUN Connection Fe, CrNiFigure A.5 Across the ARC SET-UPSFigure A.7 Figure A.9 8INSTALLATIONA-8Operation Definition of Welding Terms Recommended Power SourcesRecommended Processes Process LimitationsCase Front Controls See Figure b.1 DescriptionAnalog Voltmeter Wire Feed Speed, CV Operation Wire Feed Speed KNObMinimum Arc Volts Maximum WFS Extra TorquePolarity LED Figure b.2 Internal ControlsCV/CC Switch Internal Controls DescriptionCold Feed PUSHbUTTON Figure b-3 Constant Current Wire WeldingRear Controls ItemdescriptionGAS Purge PUSHbUTTON POWER-UP SequenceFlow Meter ScfhFactory Installed Equipment AccessoriesWire Type Drive Roll KitsAccessories Kit Accessories K1500-5 Gun Receiver Bushing compatible Installation of the K590-6 Water Cooling KIT Routine Maintenance MaintenancePeriodic Maintenance CALIbRATION SpecificationTo change the wire feed speed calibration See Figure D.2 Wire Feed Speed ValidationModel gearing BOARDElectric Shock can kill TROUbLESHOOTINGSymptoms PRObLEMSFault Code Description Possible Adjustments POSSIbLEOutput Problems TROUbLESHOOTING Diagrams LN-25 PRO Across the ARCModel Diagrams Dimension Print LN-25 PRO Across the ARC Model Precaucion Warnung