Lincoln Electric IM843-C manual Idler Operation, Auxiliary Power

Page 15

B-3

OPERATION

B-3

IDLER OPERATION

Start the engine with the “Idler” switch in the “High” position. Allow it to run at high idle speed for several minutes to warm the engine. See Specifications for operating speeds.

The idler is controlled by the “Idler” toggle switch on the welder control panel. The switch has two posi- tions as follows:

1.In the “High” position, the engine control unit increases the engine to high idle speed.

2.In the “Auto” / position, the idler oper- ates as follows:

a.When welding or drawing power for lights or tools (approximately 100 watts minimum) from the recep- tacles, the engine operates at high idle speed.

b.When welding ceases or the power load is turned off, a preset time delay of about 15 seconds starts. This time delay cannot be adjusted.

c.If the welding or power load is not re-started before the end of the time delay, the engine control unit reduces the engine to low idle speed.

AUXILIARY POWER

Start the engine and set the “IDLER” control switch to the “High Idle” mode. Voltage is now correct at the receptacles for auxiliary power. This must be done before a tripped GFCI receptacle can be reset proper- ly. See the MAINTENANCE section for detailed infor- mation on testing and resetting the GFCI receptacle.

The AC auxiliary power, supplied as a standard, has a rating of 3.0 kVA of 115/230 VAC (60 hertz).

With the 3.0 kVA, 115/230 VAC auxiliary power, one 115V duplex and one 230V duplex, grounding type receptacle are provided. The circuit is protected with circuit breakers.

The rating of 3.0 kVA permits a maximum continuous current of 13 amps to be drawn from the 230 volt duplex receptacle. Or a total of 26 amps can be drawn from the 115 volt duplex receptacle. The 115 volt duplex receptacle has a configuration which permits 20 amps to be drawn from either half. The total com- bined load of all receptacles is not to exceed 3.0 kVA.

An optional power plug kit is available. When this kit is specified, the customer is supplied with a plug for each receptacle.

When the High Speed Adjustment knob is in the MIN position, the frequency of the AC auxiliary output may be reduced to approximately 55 Hertz. It is recom- mended that the High Idle Speed Adjustment knob should be in the MAX position when using the AC auxiliary output.

CLASSIC 300D WITH KUBOTA V2203M DIESEL ENGINE

TYPICAL FUEL CONSUMPTION DATA

Low Idle (1400 RPM)-No Load

0.30 gal/hr

( 1.14

ltrs/hr)

 

 

 

 

 

High Idle (1800 RPM)-No Load

0.46 gal/hr

( 1.74

ltrs/hr)

 

 

 

 

3,000 Watts

0.61 gal/hr

( 2.31 ltrs/hr )

 

 

 

 

 

250 Amps @ 30 Volts

1.01 gal/hr

( 3.82

ltrs/hr)

 

 

 

 

300 Amps @ 32 Volts

1.32 gal/hr

( 5.00

ltrs/hr)

 

 

 

 

 

CLASSIC 300D KUBOTA

Image 15
Contents 300D Kubota California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Cycle Model Height Width Depth WeightDescription Rated DC Output DC Current RangeRated Output Duty Cycle InstallationDesign Features General DescriptionPRE-OPERATION Installation OIL Fuel PRE-OPERATION ServiceVehicle Mounting Polarity Control and Cable Sizes5INSTALLATIONA-5 Gases from Battery can explodeBattery Acid can burn eyes and skin Operation Engine OperationEngine BREAK-IN Control of Welding Current Welder OperationIdler Operation Auxiliary PowerTIG Options AccessoriesGeneral Options Stick OptionsWire Feed Module K623-1 Provides constant Wire Feed OptionsMaintenance MaintenanceBefore doing electrical work, disconnect the bat- tery Idler MaintenanceNameplates Purging AIR from Fuel System Kubota V2203M EngineEngine Service Gfci Receptacle Testing and Reset Ting Procedure HOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service FacilityClosed Electronic Idler Troubleshooting GuideSensing PCB Engine Repair Facility Irregular running of the engine Air mixed in the fuel system Troubleshooting Engine Protection Light not com Broken Light Bulb Enhanced Diagram DiagramsDiagrams Diagrams Diagrams Diagrams Kubota Aviso DE Keep your head out of fumes Turn power off before servicing