Lincoln Electric IM605 Output Connections, Connections for TIG Gtaw Welding, TIG Torch Connection

Page 11

4

INSTALLATION

4

INPUT LEADS L1 & L2 USE INSULATED BARREL RING TERMINALS TO FIT #10-32

STUDS PROVIDED.

￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿

Electrode/Gas Output Receptacle on the front of the welder and turn it clockwise until it is tight. This is a quick connect terminal and also provides the gas con- nection for the shielding gas to the torch.

WARNING

￿￿ ￿￿

(DO NOT REMOVE)

￿￿

￿￿

To avoid receiving a high frequency shock, keep the TIG torch and cables in good condition.

__________________________________________

WORK CABLE CONNECTION

A work cable with attached work clamp is factory con- nected to the Square Wave TIG 175. To minimize high frequency interference, refer to Machine Grounding and High Frequency Interference Protection section

FOR 220-240V: CONNECT COPPER LINK TO H2

FOR 380V: CONNECT COPPER LINK TO H3

FOR 400-415V: CONNECT COPPER LINK TO H4 (AS SHOWN)

FIGURE A.1 Reconnect Leads

OUTPUT CONNECTIONS

ELECTRODE/GAS OUTLET

RECEPTACLE

WORK CABLE & CLAMP

FIGURE A.2 Location of Output Connections

CONNECTIONS FOR TIG (GTAW) WELDING

TIG TORCH CONNECTION

Refer to Included Equipment in the Operation Section of this manual for TIG welding equipment which is included with the Square Wave TIG 175.

A TIG welding torch with cable and connector is sup- plied with the welder. Turn the Power Switch “OFF”. Connect the torch cable quick connect plug into the

of this manual for the proper procedure on grounding the work clamp and work piece.

SHIELDING GAS CONNECTION

Obtain the necessary inert shielding gas (usually argon). Connect a cylinder of gas with a pressure reg- ulator and flow gage. Install a gas hose between the regulator and gas inlet (located on the rear of the welder). The gas inlet has a 5/16-18 right hand female thread; CGA #032.

WARNING

CYLINDER could explode if damaged.

•Keep cylinder upright and chained to a support.

•Keep cylinder away from areas where it could be damaged.

•Never allow the torch to touch the cylinder.

•Keep cylinder away from live electrical circuits.

•Maximum inlet pressure 150 psi.

___________________________________________

The optional undercarriage features a pivoting platform that simplifies loading and unloading of gas cylinders. A cylinder is loaded by leaning it slightly sideways and rolling it toward the platform. The cylinder’s weight will push the platform downward against the floor, forming a ramp. At this point, the cylinder may be rolled up the platform into its final position. Secure the cylinder in place with the provided chain. Unload by following these steps in reverse.

SQUARE WAVE TIG 175

Image 11
Contents Square Wave TIG California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Square Wave TIG InstallationLifting and Moving Select Suitable LocationElectric Shock can kill StackingInput Supply Connections Input Reconnect ProcedureTIG Torch Connection Output ConnectionsConnections for TIG Gtaw Welding Work Cable ConnectionStick Electrode Cable and Work Cable Connection Remote Control ConnectionConnections for Stick Smaw Welding Included Equipment Safety PrecautionsOperation General DescriptionPower Switch & Light Turns power on Controls and SettingsBenefits of the Square Wave Design Welding in TIG ModeRemote Control Operation Operating StepsGtaw Process Welding in Stick ModeRecommended Electrode Amperage Ranges Square Wave TIG Smaw ProcessOptional Accessories AccessoriesFAN Motor or FAN Blade Replacement MaintenanceSafety Precautions Routine and Periodic MaintenanceHOW to USE Troubleshooting Guide TroubleshootingCourse of Action SymptomsPossible Areas Troubleshooting Square Wave TIG APR96 TIG Mode ProblemsTIG Welding Problems Troubleshooting Field Service Facility for technical Problems Possible AreasSymptoms Misadjustmentss Course of Action Wiring Diagram Square Wave TIG Square Wave TIG $700.00 Basic CoursePrecaucion Aviso DE