Lincoln Electric 350-SA manual Optional Features

Page 9

OPTIONAL FEATURES

Power Plug Kit (K802C)

Accessory Set (K703)

Includes electrode and work cables, headshield, work clamp, and electrode holder.

Ether Start Kit (K793) for Perkins Engine

When frequent starting is expected below -12°C, (10°F) remove the “thermostart” system and install the optional ether start kit to provide maximum cold weather starting assistance. Ether starting should only be used as required since indiscriminate application will contribute to shortened engine life.

(Available for field installation only).

Hi-Freq™ (K799)

Provides high frequency plus gas valve for DC TIG welding. (Request Publication E385).

Optional field installed water valve kit available. Order

K844.

A power plug kit for the auxiliary power receptacles is available. (Provides a plug for each receptacle).

Trailer (K769)

Two-wheeled trailer for in-plant and yard towing only. (For highway use, consult applicable federal, state, and local laws regarding possible requirements for brakes, lights, fenders, etc.)

Trailer (K913)

Two-wheeled highway trailer with steel, torsion-bar axle, 54” (137cm) wheel track. Low sway, low center- of-gravity. Sturdy tread plate platform. Choice of 3 hitches. Add on fender & light package. For highway use, consult applicable local laws regarding possible additional requirements.

Order: K913-1 Base Trailer

K913-2 Ball Hitch

K913-3 Lunette Eye Hitch

K913-4 Clevis Pin Hitch

K913-5 Fender & Light Kit

Linc-Thaw™ (L2964-5) Control Unit

Includes meter and fuses to protect welder when thawing frozen water pipes.

WARNING

Pipe Thawing IS NOT a CSA approved procedure. If not done properly, it can result in fire, explosion, damage to wiring which may make it unsafe, damage to pipes, burning up the welder, or other hazards.

Do not use a welder to thaw pipe before reviewing Lincoln Bulletin E695.1 (dated October 1987 or later.)

------------------------------------------------------------------------

Mufflers

Mufflers are standard on the 350-SA Perkins.

Wire Feed Module (K623-1)

The Wire Feed Module is field-installed on the K1314-4 and factory-installed on the K1314-5 to provide CV (constant voltage) output for semiautomatic welding. Output rated at 250 Amps at 35 Volts with a 60% Duty Cycle and 310 Amps at 32 Volts with a 35% Duty Cycle.

DIMENSIONS

See dimension Print M8869-24 at the rear of this manual.

8

Image 9
Contents SA Perkins Safety Depends on YouSafety Electric Shock can kill Iii Welding Sparks can cause fire or explosionPrécautions DE Sûreté Thank You Table of Contents Design Summary General DescriptionOptional Features Machine SpecificationsSafety Precautions PRE-OPERATION InstallationMachine Grounding Exhaust Spark ArresterRecommended Copper Cable Sizes Polarity Control & Cable SizesPRE-OPERATION Service Engine Operation Starting the Perkins D3.152 EngineStopping the Perkins D3.152 Engine Duty Cycle Welder OperationControl of Welding Current Idler OperationGeneral Instructions for Diesel Engine Welders MaintenanceCommutator & Brushes BearingsTroubleshooting Idler MaintenanceNameplates Trouble Cause What to do Flashing the Fields AC Auxiliary PowerElectronic Idler Troubleshooting Guide SA Wiring Diagram Dimension Print New Lessons in Arc Welding How To Read Shop DrawingsNeed Welding Training? $700.00Precaucion Warnung Limited Warranty