TROUBLESHOOTING (Continued)
|
|
|
|
|
|
|
|
|
|
|
| TROUBLE |
|
| CAUSE |
|
| WHAT TO DO |
| ||
| D. Welding current too great or |
|
| 1. | Exciter output low causing low |
|
| 1. | Check exciter field circuit. |
|
| too small compared to |
|
|
| output compared to dial |
|
|
|
|
|
| indication on the dial. |
|
|
| indication. |
|
|
|
|
|
|
|
|
| 2. | Operating speed too low or high. |
|
| 2. | Adjust speed screw on governor |
|
|
|
|
|
|
|
|
|
| for 1800 RPM operating speed. |
|
|
|
|
|
|
|
|
|
|
|
|
| E. Arc continuously pops out. |
|
| 1. | “Current Range Selector” switch |
|
| 1. | Set the switch at the center of |
|
|
|
|
|
| may be set at an intermediate |
|
|
| the current range desired. |
|
|
|
|
|
| position. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1)FLASHING THE FIELDS
AC Auxiliary Power:
1.Stop the engine welder and remove the cover from the exciter.
2.Turn the “Fine Adjustment Control” (rheostat) to “100” on the dial.
3.Using a 12 volt automotive battery, connect its negative terminal to the negative brushholder. The negative brushholder is the one nearest to the rotor lamination. See the wiring diagram. With the engine NOT running, touch the positive battery terminal to the positive brushholder. Remove the battery from the circuit.
4.Replace the exciter cover. Start the welder and the generator voltage should build up.
– 19 –