OPERATION |
CONTROLS AND SETTINGS All welder/generator controls are located on the Output Control Panel. Gasoline engine controls are mounted on the engine. See Figure B.1 and the figures in engine operation section.
OUTPUT PANEL CONTROLS
8 | 1 | 7 | 2 |
|
|
|
6
5
3 or 4 | FIGURE B.1 |
WELDER/GENERATOR CONTROLS
See Figure B.1 for the location of the following features:
1.CURRENT CONTROL DIAL: Adjusts continuous cur- rent output. The amperages on the dial correspond to the approximate amperages needed for specific Lincoln welding electrodes.
2.20 AMP CIRCUIT BREAKER: Provides overload cur- rent protection for the 120 Volt and 240 Volt Receptacles
3.WELD POSITIVE OUTPUT TERMINAL: Provides the connection point for either the electrode holder or the work cable. (Because the OUTBACK™ 145 is a DC output machine, either output terminal can be used for either cable.)
4.WELD NEGATIVE OUTPUT TERMINAL: Provides the connection point for either the electrode holder or the work cable. (Because the OUTBACK™145 is a DC output machine, either output terminal can be used for either cable.)
5.GROUND STUD: Provides a connection point for connecting the machine case to earth ground for the safest grounding procedure.
6.240 VOLT RECEPTACLE: Connection point for sup- plying 250 volt power to operate one electrical device.
7.120 VOLT DUPLEX RECEPTACLES (2): Connection point for supplying 120 volt power to operate one or has run for maintenance purposes.
8.HOUR METER: Records the time that the engine has run for maintenance purposes.
OUTBACK™ 145
¤