Lincoln Electric 225 GXT manual Auxiliary Power While Welding, Simultaneous Welding and Power

Page 15

A-8

INSTALLATION

A-8

AUXILIARY POWER WHILE WELDING

Simultaneous welding and power loads are permitted by following Table I. The permissible currents shown assume that current is being drawn from either the 120V or 240V supply (not both at the same time). Also, the “Output Control” is set at “10” for maximum auxiliary power.

TABLE I

SIMULTANEOUS WELDING AND POWER

Output Selector

Permissible Power

Permissible Auxiliary

 

 

Setting

Watts (Unity Power

Current in Amperes

 

 

Factor)

@ 120V *-or- @ 240V

 

 

 

 

 

Max. Stick or Wire

 

 

 

 

Feed Setting

None

0

0

 

 

 

 

 

 

 

145

Stick Setting

3450

32**

16

 

 

 

 

 

 

 

90

Stick Setting

6000

50**

25

 

 

 

 

 

 

No Welding

9000

76**

38

 

 

 

 

 

 

 

*Each duplex receptacle is limited to 20 amps.

**Not to exceed 40A per 120VAC branch circuit when

splitting the 240 VAC output.

STANDBY POWER CONNECTIONS

The RANGER® 225 GXT is suitable for temporary, standby, or emergency power using the engine manu- facturerʼs recommended maintenance schedule.

The RANGER® 225 GXT can be permanently installed as a standby power unit for 240V-3 wire, single phase 38 ampere service.

WARNING

(Connections must be made by a licensed electri- cian who can determine how the 120/240V power can be adapted to the particular installation and comply with all applicable electrical codes.) The following information can be used as a guide by the electrician for most applications (refer also to the connection diagram shown in Figure 1.)

-------------------------------------------------------------------------

1.Install a double pole, double throw switch between the power company meter and the premises dis- connect.

Switch rating must be the same or greater than the customerʼs premises disconnect and service over- current protection.

2.Take necessary steps to assure load is limited to the capacity of the RANGER® 225 GXT by installing a 40 amp 240V double pole circuit break- er. Maximum rated load for the 240V auxiliary is 38 amperes. Loading above 38 amperes will reduce output voltage below the allowable -10% of rated voltage which may damage appliances or other motor-driven equipment.

3.Install a 50 amp 120/240V plug (NEMA type 14-50) to the Double Pole Circuit Breaker using No. 8, 4 conductor cable of the desired length. (The 50 amp 120/240V plug is available in the optional plug kit.)

4.Plug this cable into the 50 amp 120/240V recepta- cle on the RANGER® 225 GXT case front.

RANGER® 225 GXT

Image 15
Contents Ranger 225 GXT California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Technical Specifications Ranger 225 GXT K2733-1 InstallationTowing Safety PrecautionsMachine Grounding Spark ArresterPRE-OPERATION Service Battery ConnectionsGasoline Angle of Operation Additional Safety PrecautionWelding Output Cables Total Combined Length of Electrode and Work CablesLocation / Ventilation Connection of Lincoln Electric Wire FeedersAdditional Safety Precautions InstructionsWelder Operation Auxiliary PowerType Common Electrical Devices Possible Concerns Electrical Device USE with the Ranger 225 GXTAuxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections Connection of Ranger 225 GXT to Premises Wiring Welder Controls Function and Operation Engine SwitchOperation General DescriptionRanger 225 GXT Approximate Fuel Consumption Polarity SwitchStopping the Engine STARTING/SHUTDOWN InstructionsBREAK-IN Period Starting the EngineTIG Constant Current Welding Wire Feed Welding Processes Constant VoltageWelding Process Stick Constant Current WeldingStick Auto K1745-1 Welding GAS Cylinder LPG Tank Holder AccessoriesTIG Wire FeedRecommended Equipment StickEngine OIL Change MaintenanceSafety Precautions Routine MaintenanceOIL Filter Change AIR Cleaner and Other MaintenanceEngine Adjustments HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Enhanced Diagam DiagramsM20266 Dimension Print Ranger 225 GXT Aviso DE Keep your head out of fumes Turn power off before servicing