B-1

OPERATION

B-1

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have thoroughly read the engine manufacturerʼs manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

Always operate the welder with the hinged door closed and the side panels in place.

Read carefully the Safety Precautions page before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Instruction Manual.

------------------------------------------------------------------------

GENERAL DESCRIPTION

The RANGER® 225 GXT is a twin-cylinder, gasoline driven, multiprocess arc welder and AC power gener- ator. It is built in a heavy gauge steel case for durabili- ty on the job site.

WELDER CONTROLS - FUNCTION AND OPERATION

ENGINE SWITCH

The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine.

When placed in the “OFF” position, the ignition circuit is de-energized to shut down the engine.

When held in the “START” position, the engine starter motor is energized.

When in “HIGH IDLE” ( ) position, the engine will run continuously at high idle.

When in “AUTO IDLE” ( / ) position, the engine will run continuously and the idler operates as follows:

Welding

When the electrode touches the work, the welding arc is initiated and the engine accelerates to full speed.

After welding ceases (and no auxiliary power is being drawn), the engine will return to low idle after approximately 10 to 14 seconds.

Auxiliary Power

With the engine running at low idle and auxiliary power for lights or tools is drawn (approximately 100-150 watts or greater) from the receptacles, the engine will accelerate to high speed. If no power is being drawn from the receptacles (and not welding) for 10-14 seconds, the idler reduces the engine speed to low idle.

RANGER® 225 GXT

Image 17
Contents Ranger 225 GXT California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Technical Specifications Ranger 225 GXT K2733-1 InstallationMachine Grounding Safety PrecautionsSpark Arrester TowingGasoline PRE-OPERATION ServiceBattery Connections Welding Output Cables Additional Safety PrecautionTotal Combined Length of Electrode and Work Cables Angle of OperationAdditional Safety Precautions Connection of Lincoln Electric Wire FeedersInstructions Location / VentilationWelder Operation Auxiliary PowerType Common Electrical Devices Possible Concerns Electrical Device USE with the Ranger 225 GXTStandby Power Connections Auxiliary Power While WeldingSimultaneous Welding and Power Connection of Ranger 225 GXT to Premises Wiring Operation Engine SwitchGeneral Description Welder Controls Function and OperationRanger 225 GXT Approximate Fuel Consumption Polarity SwitchBREAK-IN Period STARTING/SHUTDOWN InstructionsStarting the Engine Stopping the EngineWelding Process Wire Feed Welding Processes Constant VoltageStick Constant Current Welding TIG Constant Current WeldingStick Auto K1745-1 Welding GAS Cylinder LPG Tank Holder AccessoriesRecommended Equipment Wire FeedStick TIGSafety Precautions MaintenanceRoutine Maintenance Engine OIL ChangeOIL Filter Change AIR Cleaner and Other MaintenanceEngine Adjustments HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Enhanced Diagam DiagramsM20266 Dimension Print Ranger 225 GXT Aviso DE Keep your head out of fumes Turn power off before servicing