Lincoln Electric 225 GXT manual Welding Process, Stick Constant Current Welding, ARC Gouging

Page 20

B-4

OPERATION

B-4

WELDING PROCESS

For any electrodes the procedures should be kept within the rating of the machine. For electrode infor- mation see the appropriate Lincoln publication.

STICK (CONSTANT CURRENT) WELDING

Connect welding cables to the "TO WORK” and "ELECTRODE” studs. Start the engine. Set the "Polarity” switch to the desired polarity. The “RANGE” switch markings indicate the maximum current for that range as well as the typical electrode size for that range. The “OUTPUT” Control provides fine adjust- ment of the welding current within the select range. For maximum output within a selected range set the “OUTPUT” Control at 10. For minimum output within a selected range set the “OUTPUT” Control at 5. (“OUT- PUT” Control settings below 5 may reduce arc stabili- ty) For best overall welding performance set the “RANGE” Switch to the lowest setting and the OUT- PUT” Control near the maximum to achieve the desired welding current.

RANGE SETTING

TYPICAL

CURRENT RANGE

 

ELECTRODE SIZE

 

 

 

 

90 MAX.

3/32

40 TO 90 AMPS

 

 

 

145 MAX.

1/8

70 TO 145 AMPS

 

 

 

210(DC)/225(AC)

5/32

120 TO 210(DC),

 

 

225(AC) AMPS

 

 

 

The RANGER® 225 GXT can be used with a broad range of AC and DC stick electrodes. See “Welding Tips 1” included with the RANGER® 225 GXT for electrodes within the rating of this unit and recom- mended welding currents of each.

TIG (CONSTANT CURRENT) WELDING

The RANGER® 225 GXT can be used in a wide variety of AC and DC Tungsten Inert Gas (TIG) welding applications for AC TIG Welding up to 200 amps and DC TIG welding up to 210 amps.

The K930 [ ] TIG Module installed on a RANGER® 225 GXT provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding processes. The TIG Module allows full range output control.

When using the RANGER® 225 GXT for AC TIG welding of alu- minum the following settings and electrodes are recommended:

SETTINGS FOR PURE TUNGSTEN

TUNGSTEN

RANGE SWITCH

APPROXIMATE

DIAMETER (in.)

SETTINGS

CURRENT RANGE

 

 

 

1/8

80 or 130

100 - 300 Amps

3/32

80

45

-

140

Amps

1/16

80

45

-

100

Amps

 

 

 

 

 

 

SETTINGS FOR 1% THORIATED TUNGSTEN

TUNGSTEN

RANGE SWITCH

APPROXIMATE

DIAMETER (in.)

SETTINGS

CURRENT RANGE

 

 

 

 

 

 

1/8

80, 130, or 180

80

-

225

Amps

3/32

80 or 130

50

-

180

Amps

1/16

80

45 - 120 Amps

 

 

 

 

 

 

For AC TIG Welding, the maximum TIG Welding out- put currents on each range setting will be approxi- mately 50% higher than those marked on the name- plate. This is due to the special nature of the AC TIG welding arc. Do not AC TIG weld on the 210DC/225AC Amp setting. The output may exceed the rating of the RANGER® 225 GXT.

WIRE FEED WELDING PROCESSES (CONSTANT VOLTAGE)

The Innershield® electrode recommended for use with the RANGER® 225 GXT is NR®-211-MP. The elec- trode sizes and welding ranges that can be used with the RANGER® 225 GXT are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

 

.035

80

- 110

75A to 120A

.045

70

- 130

120A to 170A

.068

40

- 90

125A to 210A

 

 

 

 

The RANGER® 225 GXT is recommended for limited “MIG” welding (GMAW - gas metal arc welding). The recommended electrodes are .030” and .035” L-50 and L-56. They must be used with a blended shield- ing gas such as C25 (75% Argon - 25% CO2). The welding ranges that can be used with the RANGER®

225 GXT are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

 

.030

75

- 300

50A to 130A

.035

100

- 250

90A to 175A

 

 

 

 

ARC GOUGING

The RANGER® 225 GXT can be used for limited arc gouging.

Set the Range switch to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table:

ELECTRODE SETTING

CURRENT RANGE (DC, electrode positive)

 

 

 

 

1/8

30

-

60 Amps

5/32

90

-

150 Amps

3/16

150 - 250 Amps

 

 

 

 

RANGER® 225 GXT

Image 20
Contents Ranger 225 GXT Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specifications Ranger 225 GXT K2733-1Safety Precautions Machine GroundingSpark Arrester TowingGasoline PRE-OPERATION ServiceBattery Connections Additional Safety Precaution Welding Output CablesTotal Combined Length of Electrode and Work Cables Angle of OperationConnection of Lincoln Electric Wire Feeders Additional Safety PrecautionsInstructions Location / VentilationAuxiliary Power Welder OperationElectrical Device USE with the Ranger 225 GXT Type Common Electrical Devices Possible ConcernsStandby Power Connections Auxiliary Power While WeldingSimultaneous Welding and Power Connection of Ranger 225 GXT to Premises Wiring Engine Switch OperationGeneral Description Welder Controls Function and OperationPolarity Switch Ranger 225 GXT Approximate Fuel ConsumptionSTARTING/SHUTDOWN Instructions BREAK-IN PeriodStarting the Engine Stopping the EngineWire Feed Welding Processes Constant Voltage Welding ProcessStick Constant Current Welding TIG Constant Current WeldingStick Auto Accessories K1745-1 Welding GAS Cylinder LPG Tank HolderWire Feed Recommended EquipmentStick TIGMaintenance Safety PrecautionsRoutine Maintenance Engine OIL ChangeAIR Cleaner and Other Maintenance OIL Filter ChangeEngine Adjustments Troubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Diagrams Enhanced DiagamM20266 Dimension Print Ranger 225 GXT Aviso DE Keep your head out of fumes Turn power off before servicing