PROBLEM

CAUSE

CORRECTION

Excessive

Defective

Move the pressure switch lever to the

tank

pressure

 

"OFF" position. If the unit doesn't shut

pressure -

switch.

 

off, unplug. If the electrical contacts are

safety valve

 

 

welded together, replace the pressure

pops off.

Improper

 

switch.

 

wiring.

If the contacts are good, check to see if

 

 

 

 

 

the pin in the pressure release valve is

 

 

 

stuck. If it does not move freely, replace

 

 

 

the valve.

 

 

Adjust or replace pressure switch.

 

 

 

Air leaks at

Fittings are

Tighten fittings where air can be heard

fittings.

not tight

escaping. Check fittings with a soap and

 

enough.

water solution. DO NOT OVER TIGHTEN.

 

 

 

Air leaks at

Defective or

A defective check valve results in a

or inside

dirty check

constant air leak at the pressure release

check

valve.

valve where there is a pressure in the tank

valve.

 

and the compressor is shut off. Remove

 

 

and clean or replace check valve. DO

 

 

NOT OVER TIGHTEN.

 

 

 

Air leaks at

Defective

Contact a trained service technician.

pressure

pressure

 

 

switch

switch

 

 

unloader

unloader

 

 

valve.

valve, or

 

 

 

defective

 

 

 

check valve.

 

 

 

 

 

Air leaks in

Defective air

Air tank must be replaced. Do not repair

air tank or

tank.

the leak. WARNING DO NOT DRILL

at air tank

 

INTO, WELD OR OTHERWISE MODIFY

welds.

 

AIR TANK OR IT WILL WEAKEN. THE

 

 

TANK CAN RUPTURE OR EXPLODE.

 

 

 

Air leaks

Blown head

Replace gasket or contact Authorized

between

gasket.

Service Technician.

head and

 

 

 

valve plate.

 

 

 

 

 

 

 

Page 14

Image 14
Contents Minimum Circuit Requirement 15 Amps Specification ChartScfm @ 40 Psig Scfm @ 90 Psig Table of Contents Risk Important Safety InstructionsHazard What can Happen HOW to Prevent IT UnsafeTank AccessoriesRisk of Air BurstingExplosion or ElectricShock FireAir Risk fromCompressed Moving PartsGeneral Information GlossaryDuty Cycle ON-RECEIPT InspectionStorage Description OperationInstallation BREAK-IN Procedures Location of the AIR CompressorAmp Length Rating Cord in Feet Initial Start Up ProcedureExtension Cords PipingWhen you are finished Operating ProceduresDaily Start-up Checklist Cold Weather Conditions MaintenanceRoutine Maintenance Schedule Filling with OilMotor Service InstructionsUnits with External Brass Check Valve Replacement INTO, Weld or Otherwise Modify Troubleshooting GuideNot Over Tighten AIR Tank or IT will WEAKEN.Problem Cause Correction Problem Cause Correction Colorado Arizona Illinois NEW YorkCalifornia FloridaMakita Limited ONE Year Warranty Warranty PolicyMail this Portion Makita U.S.A., Inc