amount of oil may be present in the pump upon receipt of the air compressor. This is due to factory testing and does not mean the pump contains oil.
CAUTION:
Initial Start Up Procedure:
1.Open the air receiver's drain valve.
2.Plug power supply cord into correct power source.
3.Run the compressor for a minimum of twenty (20) minutes in the
4.Close air receiver drain valve. Your compressor is now ready for use.
Extension Cords
To avoid voltage drop, power loss, and overheating of the motor, use extra air hose instead of an extension cord. Low voltage can cause damage to the motor.
If an extension cord must be used:
·Use only an approved
·Make sure the extension cord is in good condition.
Please see the chart below as the MINIMUM requirements:
Amp |
| Length of |
| ||
Rating | Cord in Feet | ||||
|
|
|
|
|
|
(120 Volts) | 25' |
| 50' | 100' | 150' |
|
|
|
|
|
|
16 |
| 14 | 10 | 8 | |
|
|
|
|
|
|
16 |
| 12 | 10 | 8 | |
|
|
|
|
|
|
16 |
| 12 | 10 | 8 | |
|
|
|
|
|
|
14 |
| 12 | 8 | 8 | |
|
|
|
|
|
|
14 |
| 12 | 8 | 8 |
Piping
Plastic or PVC pipe is not designed for use with compressed air. Regardless of its indicated pressure rating, plastic pipe can burst from air pressure. Use only metal pipe for air distribution lines.
If a pipe line is necessary, use pipe that is the same size, or larger than, the air tank outlet. Piping that is too small will restrict the flow of air. If piping is over 100 feet long, use the next larger size. Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before underground lines are covered to make sure all pipe joints are free of leaks.
Grounding Instruction WARNING: Risk of electric shock! In the event if a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The air compressor is equipped with a cord having a grounding wire with an appropriate