3-4. Changing the Standard Setting Values (Video Level)

3-4. Changing the Standard Setting Values (Video Level)

When changing the setting of black level, flare, gamma, manual knee and white clip by the user’s desire, perform the procedures below.

3-4-1. Setting Status before Changing the Setting.

. Side Panel

 

GAIN switch:

LOW (0 dB)

OUTPUT/DL/DCC +:

CAM/DCC +

WHITE BAL switch:

A

ZEBRA switch:

OFF

HYPER GAIN switch:

OFF

SET UP switch:

STD

EZ MODE button:

OFF

A.IRIS MODE:

STD

ATW button:

OFF

. Front Panel

 

FILTER control:

1 (3200 K)

SHUTTER switch:

OFF

. Lens

 

IRIS:

M (Manual)

ZOOM:

M (Manual)

3-18

3-4-2. Changing the Setting Value of Black Level

Equipment:

Waveform monitor

Test point:

VIDEO OUT connector

Procedure for changing the setting

1.Set the lens iris to the close position (C).

2.Push the WHT/BLK switch in the “BLK” direction to make a black balance.

3.SERVICE menu “PAGE 15” M.BLACK:

4.Set the black level A with the UP or DOWN switch.

M.BLACK Standard setting value = 2070 (for NTSC) 2075 (for PAL)

DXC-D35/D35WS(UC)

DXC-D35P/D35WSP(CE) V1

Page 118
Image 118
Sony DXC-D35 service manual Changing the Standard Setting Values Video Level, Setting Status before Changing the Setting