3-4. Changing the Standard Setting Values (Video Level)
When changing the setting of black level, flare, gamma, manual knee and white clip by the user’s desire, perform the procedures below.
3-4-1. Setting Status before Changing the Setting.
. Side Panel |
|
GAIN switch: | LOW (0 dB) |
OUTPUT/DL/DCC +: | CAM/DCC + |
WHITE BAL switch: | A |
ZEBRA switch: | OFF |
HYPER GAIN switch: | OFF |
SET UP switch: | STD |
EZ MODE button: | OFF |
A.IRIS MODE: | STD |
ATW button: | OFF |
. Front Panel |
|
FILTER control: | 1 (3200 K) |
SHUTTER switch: | OFF |
. Lens |
|
IRIS: | M (Manual) |
ZOOM: | M (Manual) |
3-4-2. Changing the Setting Value of Black Level
Equipment: | Waveform monitor |
Test point: | VIDEO OUT connector |
Procedure for changing the setting
1.Set the lens iris to the close position (C).
2.Push the WHT/BLK switch in the “BLK” direction to make a black balance.
3.SERVICE menu “PAGE 15” → M.BLACK:
4.Set the black level A with the UP or DOWN
switch.
M.BLACK Standard setting value = 2070 (for NTSC) 2075 (for PAL)